Share:


Bitzer 2-Stage Semi-Hermetic Compressor



BITZER REFRIGERATION COMPRESSORS

BITZER 2-Stage Semi-Hermetic Reciprocating Compressor

ECOLINE 2-Stage | S4T–S6F Standard Series & S66 Tandem Series

Engineered for demanding low-temperature and ultra-low-temperature refrigeration, combining robust semi-hermetic construction, two-stage compression and a broad range of compressor capacities.

2-Stage Compression Low & Ultra-Low Temperature Standard & Tandem Commercial & Industrial
Reliable Compression for Demanding Refrigeration Applications

BITZER ECOLINE 2-Stage compressors are designed for refrigeration systems operating at very low evaporating temperatures. Their two-stage compression process divides the overall pressure increase between low-pressure and high-pressure stages, supporting efficient operation across demanding pressure ratios when correctly engineered.

✨ Why Choose BITZER 2-Stage Compressors?

❄️ Ultra-Low Temperature

Designed for deep-freezing and demanding low-temperature refrigeration applications.

⚙️ Two-Stage Compression

Low-pressure and high-pressure compression stages within a purpose-built compressor system.

🔩 Robust Construction

Optimised drive mechanism and durable semi-hermetic reciprocating design.

📈 Long-Term Value

A strong choice for projects prioritising operating efficiency, reliability and lifecycle value rather than initial price alone.

📊 Compressor Range Overview

7

Standard Models

S4T, S4N, S4G, S6J, S6H, S6G and S6F.

19.7–101.1

Standard Displacement

m³/h theoretical displacement at 50 Hz.

127–202.2

Tandem Displacement

m³/h at 50 Hz across the listed S66 tandem range.

📋 Available BITZER 2-Stage Compressor Models

Click a category to expand the model table.

01 / Standard 2-Stage Compressors — S4T to S6F
Model Displacement at 50 Hz Configuration
S4T-5.2(Y) 19.7 m³/h Standard
S4N-8.2(Y) 28.0 m³/h Standard
S4G-12.2(Y) 42.3 m³/h Standard
S6J-16.2(Y) 63.5 m³/h Standard
S6H-20.2(Y) 73.6 m³/h Standard
S6G-25.2(Y) 84.5 m³/h Standard
S6F-30.2(Y) 101.1 m³/h Standard
02 / Tandem 2-Stage Compressors — S66 Series
Model Displacement at 50 Hz Configuration
S66J-32.2(Y) 127.0 m³/h Tandem
S66H-40.2(Y) 147.2 m³/h Tandem
S66G-50.2(Y) 169.0 m³/h Tandem
S66F-60.2(Y) 202.2 m³/h Tandem
Technical Note: Displacement is not refrigerating capacity. Actual cooling capacity depends on refrigerant, evaporating temperature, condensing temperature, subcooling arrangement and operating conditions. Model availability, suffixes and specialised variants require confirmation.

⚙️ Technical Features

Optimised Drive Mechanism

Purpose-designed reciprocating mechanism for reliable low-temperature operation.

Efficient Motor Design

Integrated motor design suitable for the compressor's intended operating range.

Two Compression Stages

Dedicated low-pressure and high-pressure compression stages for demanding refrigeration conditions.

Refrigerant Options

Selected HFC/HCFC and lower-GWP refrigerants, subject to exact model approval and operating limits.

System Integration

Can be engineered with appropriate liquid subcooling, injection control and system protection.

Single & Tandem Designs

Different displacement options allow selection for small and larger refrigeration system requirements.

🏭 Typical Applications

Deep Freezing

Industrial and commercial deep-freezing refrigeration systems.

Ultra-Low Temperature

Specialised refrigeration processes requiring very low evaporating temperatures.

Cold Storage

Low-temperature cold rooms and frozen-goods storage facilities.

Process & Marine Cooling

Selected industrial process and marine refrigeration applications.

📐 Compressor Selection Guide

Please provide these details so our team can assist with the correct model selection:

01 / Refrigerant Type of refrigerant used
02 / Cooling Capacity Required refrigeration capacity in kW
03 / Evaporating Temperature Design evaporating temperature in °C
04 / Condensing Temperature Design condensing temperature in °C
05 / Power Supply Voltage, phase and frequency
06 / System Arrangement Single, tandem, subcooling and control requirements
Important Engineering Note: Compressor selection must follow the official BITZER operating envelope and approved refrigerant, oil, motor and accessory combinations. Refrigerant injection, subcooling, oil management and protection components must be selected according to the actual system design.
BITZER REFRIGERATION SOLUTIONS

Looking for a BITZER 2-Stage Compressor?

Contact our team for model selection, technical enquiries, availability and quotation.