Share:


Elitech Digital Manifold Set MS-1000 (2 Valves)



Elitech MS-1000 2-Valve Digital Manifold Gauge

Professional digital manifold for pressure and temperature measurement in refrigeration, air conditioning, cold room and HVAC/R service applications.

MS-1000 2-Valve Digital Manifold ±0.5% FS HVAC / Refrigeration

Elitech MS-1000 Digital Manifold

The Elitech MS-1000 is a professional 2-valve digital manifold gauge designed for daily inspection, installation, testing and maintenance of refrigeration and air-conditioning systems.

It combines high and low pressure measurement with dual temperature measurement and built-in superheat and subcooling calculation, giving HVAC/R technicians useful system information directly on the digital display.

Its large LCD display, multiple refrigerant support and digital temperature-compensated pressure sensors make the MS-1000 a practical alternative to conventional mechanical manifold gauges.

Pressure Range -14.5 to 800 psi
Pressure Accuracy ±0.5% FS
Temperature Range -40°C to +150°C
Valve Configuration 2-Valve

Key Features

High & Low Pressure

Measures refrigeration system high-side and low-side pressure digitally for convenient HVAC/R system diagnosis.

Dual Temperature Measurement

Supports two external temperature measurement channels for monitoring refrigeration system pipe temperatures.

Superheat Calculation

Built-in calculation helps technicians evaluate superheat during compatible refrigeration and air-conditioning system servicing.

Subcooling Calculation

Automatically calculates subcooling when the required pressure and temperature measurements are available.

Temperature Compensation

Dual temperature-compensated pressure sensor design helps provide stable pressure measurement performance.

Large Digital Display

Large LCD display provides clear pressure, temperature and servicing information for field use.

Multiple Refrigerants

Built-in refrigerant database supports a wide range of common HVAC/R refrigerants.

Low Power Consumption

Designed for extended field operation with approximately 200 hours of battery life when the backlight is switched off.

Elitech MS-1000 Technical Specifications

Specification MS-1000
Model MS-1000
Product Type 2-Valve Digital Manifold
Pressure Measurement Range -14.5 to 800 psi
Pressure Accuracy ±0.5% FS
Pressure Resolution 0.5 psi
Pressure Units psi, kg/cm², kPa, MPa, bar
Temperature Range -40°C to +150°C / -40°F to +302°F
Temperature Accuracy ±0.5°C / ±0.9°F
Temperature Resolution 0.1°C / 0.2°F
Temperature Units °C / °F
Refrigerant Database 88 Refrigerant Types*
Pressure Connections 3 × 1/4″ SAE
Temperature Connections 2 × PS/2
Display Full-View LCD
Power Supply 3 × 1.5V AA Batteries
Battery Life Approx. 200 Hours with Backlight Off
Operating Temperature -10°C to +50°C
Storage Temperature -20°C to +60°C
Product Weight Approx. 1000 g
Bluetooth / App No – Standard MS-1000
Superheat / Subcooling Built-In Calculation
Important Model Difference

The standard MS-1000 is the non-Bluetooth version. Bluetooth, App connectivity, data recording/export and refrigerant database updating are features associated with models such as the MS-1000S.

Wide Refrigerant Support

The MS-1000 includes a built-in refrigerant database for a wide variety of refrigeration and air-conditioning service applications.

Common Refrigerants Include

R22 • R32 • R134a • R404A • R407C • R410A • R448A • R449A • R452A • R454A • R454B • R507A • R600a • R744 and many more.

*The MS-1000 manual lists 88 selectable refrigerant types. Always select the correct refrigerant before performing system calculations.

Built-In Superheat & Subcooling Calculation

One of the major advantages of the Elitech MS-1000 over a basic digital pressure gauge is its ability to combine pressure and temperature information for refrigeration system analysis.

Superheat

Helps technicians evaluate evaporator and suction-side operating conditions when servicing compatible refrigeration systems.

Subcooling

Helps technicians evaluate condenser and liquid-side operating conditions during compatible HVAC/R system commissioning and servicing.

Dual Temperature Input

Two temperature probe connections allow technicians to obtain the temperature information required for system analysis.

Suitable Applications

Cold Room Systems

Suitable for pressure and temperature measurement during cold room installation, commissioning and refrigeration maintenance.

Commercial Refrigeration

Useful for servicing compatible freezers, display cases, condensing units and commercial refrigeration equipment.

Air Conditioning

Suitable for pressure and temperature checking during air-conditioning installation, maintenance and troubleshooting.

HVAC/R Servicing

A practical digital service instrument for HVAC/R contractors, technicians and maintenance teams.

System Commissioning

Allows technicians to monitor system operating conditions during refrigeration system start-up and commissioning.

Troubleshooting

Pressure, temperature, superheat and subcooling information can assist technicians when evaluating refrigeration system performance.

Why Choose Elitech MS-1000?

Digital Accuracy

Provides clear digital pressure readings with ±0.5% FS pressure accuracy.

All-in-One Measurement

Combines pressure and dual temperature measurement within one professional HVAC/R service instrument.

System Calculation

Built-in superheat and subcooling calculation helps simplify refrigeration system analysis.

Large Display

Large digital LCD makes field readings clearer and easier to monitor.

Multiple Refrigerants

Supports numerous refrigerants for different refrigeration and air-conditioning applications.

Professional HVAC/R Tool

Designed for refrigeration technicians, air-conditioning contractors and professional service teams.

Recommended For

Professional Refrigeration & HVAC/R Service

✓ Refrigeration Technicians
✓ Cold Room Installation Teams
✓ Cold Room Service Technicians
✓ Air Conditioning Contractors
✓ Commercial Refrigeration Contractors
✓ HVAC Maintenance Departments
✓ Refrigeration System Installers

Important Usage Information

Before Use:

• Select the correct refrigerant in the instrument.
• Confirm system pressure is within the allowable measurement range.
• Use suitable refrigerant charging hoses and connections.
• Follow the refrigeration equipment manufacturer's specifications.
• Follow appropriate refrigerant handling and HVAC/R servicing procedures.

Note: Refrigerants have different operating pressures and safety classifications. Never assume that service procedures are identical between different refrigerants.

Elitech MS-1000 Digital Manifold Supplier Malaysia

RNA Engineering & Trading Sdn Bhd supplies Elitech MS-1000 2-Valve Digital Manifold Gauge for cold room, commercial refrigeration, air conditioning and professional HVAC/R servicing applications.

Contact our sales team for product availability and refrigeration service equipment enquiries.



 Inquiry - Elitech Digital Manifold Set MS-1000 (2 Valves)