Share:


Danfoss Plate Heat Exchanger



DANFOSS • HEAT EXCHANGER TECHNOLOGY

Danfoss Plate Heat Exchanger (PHE)

Compact and efficient Brazed Plate Heat Exchanger (BPHE) and Micro Plate Heat Exchanger (MPHE) solutions for refrigeration, chillers, heat pumps, air conditioning and HVAC applications.

Danfoss Plate Heat Exchangers provide efficient transfer of thermal energy between refrigerant, water, brine and other compatible system fluids within a compact heat exchanger.

The Danfoss range includes conventional Brazed Plate Heat Exchangers (BPHE) together with Micro Plate Heat Exchangers (MPHE) engineered for refrigeration, air-conditioning, chiller and heat-pump applications. Depending on the selected model, the heat exchanger can be used for evaporator, condenser or multifunctional heat-transfer duties.

RNA Engineering & Trading Sdn Bhd supplies selected Danfoss B3-052, B3-095, D62-E, H30-C and H30L-C plate heat exchanger models for commercial refrigeration and HVACR applications in Malaysia.

✨ Why Choose Danfoss Plate Heat Exchangers?

Designed for efficient heat transfer while keeping equipment size and internal volume compact.

⚡

High Heat Transfer

Corrugated plate technology provides a large effective heat-transfer surface within a compact footprint.

📐

Compact Construction

High thermal performance in a relatively small and space-saving heat exchanger package.

❄️

HVACR Applications

Suitable configurations are available for refrigeration, chillers, heat pumps and air-conditioning systems.

🔧

Multiple Configurations

Different plate quantities, pressure ratings, connections and heat-transfer duties are available depending on model.

🔍 BPHE & MPHE Technology

Different Danfoss heat exchanger technologies are available for different operating requirements.

BPHE

Brazed Plate Heat Exchanger

Stainless-steel heat-transfer plates are permanently brazed together to create separate flow channels. The design combines efficient heat transfer with compact construction and eliminates the conventional gasketed plate-pack arrangement.

MPHE

Micro Plate Heat Exchanger

Danfoss Micro Plate technology uses application-optimized plate geometry to achieve efficient heat transfer and compact system design for selected evaporator and condenser applications.

📋 Available Models

Selected Danfoss Plate Heat Exchangers available from RNA Engineering & Trading Sdn Bhd.

Series Danfoss Code Model Plates Typical Duty Capacity Reference*
B3-052 021B4365 B3-052-24-4.5-M-Q102 24 BPHE Application Dependent
B3-095 021H2310 B3-095-60-3.0-HQ 60 Multifunctional Application Dependent
D62-E 021H0870 D62-E-16 16 Evaporator Approx. 3.0 RT*
D62-E 021H0872 D62-E-26 26 Evaporator Approx. 4.0–5.0 RT*
D62-E 021H0873 D62-E-30 30 Evaporator Approx. 6.0 RT*
H30-C 111B6056 H30-C-18 18 Condenser Approx. 1.0–1.5 RT*
H30L-C 111B6078 H30L-C-26 26 Condenser Approx. 2.0 RT*
⚠ Capacity Selection Note: RT figures shown above are general reference values from our existing product range and should not be used as the sole basis for final heat-exchanger selection. Actual capacity varies with refrigerant, evaporating/condensing temperature, fluid temperatures, flow rate, pressure drop and other operating conditions.

🧩 Danfoss PHE Series Overview

Click each series below to view its main application and configuration.

Danfoss B3-052 Series

The Danfoss B3-052 is a compact brazed plate heat exchanger platform suitable for various refrigeration, chiller, heat-pump and heat-transfer duties depending on the selected configuration.

  • Available Code: 021B4365
  • Model: B3-052-24-4.5-M-Q102
  • Number of Plates: 24
  • Compact brazed plate construction
  • Selection depends on actual system operating conditions
Danfoss B3-095 Series

The B3-095 is a larger Danfoss brazed plate heat exchanger platform for higher-capacity refrigeration, HVAC and heat-transfer applications.

  • Danfoss Code: 021H2310
  • Model: B3-095-60-3.0-HQ
  • Number of Plates: 60
  • Maximum Working Pressure: 30 bar
  • Plate Material: AISI 316L
  • Brazing Material: Copper
  • Function: Multifunctional, with distributor
Danfoss D62-E Series — Evaporator

The Danfoss D62-E is a Micro Plate Heat Exchanger configured for evaporator duty. Refrigerant distributor configurations help support effective refrigerant distribution through the heat exchanger.

  • 021H0870: D62-E-16 — 16 Plates
  • 021H0872: D62-E-26 — 26 Plates
  • 021H0873: D62-E-30 — 30 Plates
  • Function: Evaporator
  • Maximum Working Pressure: 30 bar for listed configurations
  • Brazing: Copper-brazed construction
Danfoss H30-C Series — Condenser

The Danfoss H30-C Micro Plate Heat Exchanger is designed for compact and efficient condenser applications.

  • Danfoss Code: 111B6056
  • Model: H30-C-18
  • Number of Plates: 18
  • Function: Condenser
  • Suitable for compatible refrigeration and HVAC applications
Danfoss H30L-C Series — High-Pressure Condenser

The Danfoss H30L-C is a Micro Plate Heat Exchanger condenser configuration suitable for compatible high-density refrigerant and heat-pump applications.

  • Danfoss Code: 111B6078
  • Model: H30L-C-26
  • Number of Plates: 26
  • Function: Condenser
  • Maximum Working Pressure: 48 bar
  • Brazing Material: Copper



🏭 Typical Applications

Danfoss plate heat exchanger technology can be applied across a wide range of commercial cooling and HVAC systems.

❄️ Commercial Refrigeration Cold rooms, food storage systems and commercial refrigeration equipment.
💧 Water Chillers Compact refrigerant-to-water heat-transfer solutions for chiller systems.
♨️ Heat Pumps Selected evaporator and condenser configurations for compatible heat-pump systems.
🌬️ Air Conditioning Efficient heat-transfer solutions for commercial air-conditioning and HVAC equipment.
🧊 Evaporators Selected D62-E configurations designed specifically for evaporator duty.
🔥 Condensers H30-C and H30L-C configurations for compatible condenser applications.
⚙️ Process Cooling Compact heat transfer for compatible commercial and industrial cooling processes.
🔄 Heat Recovery Application-dependent heat-transfer solutions where energy recovery is required.

📌 Information Required for PHE Selection

A plate heat exchanger should be selected according to the actual operating conditions rather than connection size or nominal RT alone. For accurate selection, please provide:

01. Required cooling / heating capacity
02. Refrigerant or secondary fluid
03. Evaporator / condenser / liquid duty
04. Evaporating or condensing temperature
05. Fluid inlet temperature
06. Fluid outlet temperature
07. Water / brine flow rate
08. Connection & pressure requirements

Need Help Selecting a Danfoss Plate Heat Exchanger?

RNA Engineering & Trading Sdn Bhd supplies Danfoss refrigeration components and plate heat exchangers for commercial refrigeration, cold room, chiller and HVAC applications in Kuala Lumpur (KL), Selangor and throughout Malaysia.



 Inquiry - Danfoss Plate Heat Exchanger