Share:


SCM Smart Booster CO2 Transcritical Rack



SCM Frigo · Smart Booster · Model MWS

Big CO₂ performance in a small footprint

The most compact transcritical CO₂ booster rack SCM Frigo builds — sized for convenience stores, petrol marts and small supermarkets where the plant room was never designed for refrigeration.

1600 mm 750 mm Plan view to scale · height 1990 mm · 70 L receiver
Refrigerant
CO₂ / R744
Medium temperature
16.6–59.5 kW
Low temperature
3.3–8.5 kW
Models available
22

What the Smart Booster is

The Smart Booster, model code MWS, is a factory-built refrigeration rack that runs on carbon dioxide instead of synthetic refrigerant. One machine serves your chilled cabinets and, on booster models, your freezer room as well.

It was designed around a constraint most retail sites share: there is no room for a conventional rack. At 1600 mm long and 750 mm wide, it fits into plant rooms, back-of-house corners and rooftop platforms that would otherwise rule out a centralised system.

Every unit leaves the factory piped, wired, pressure tested and pre-programmed. Your contractor connects power, pipework and the gas cooler, then commissions — rather than building a system on site.

CO₂ has a global warming potential of 1, against roughly 3,900 for R404A. It sits outside every refrigerant phase-down schedule, so the system you install today will not be the system you have to re-gas at a premium in 2032.

Why customers choose it

  • It fitsThe smallest transcritical CO₂ rack in the SCM range, with the electrical panel available on the short side for tight installations.
  • It arrives readyFactory tested with parameters already set. Commissioning is measured in days, not weeks.
  • Proven componentsBITZER semi-hermetic piston compressors, CRII digital capacity modulation from 10 to 100%, maintenance-free oil separator, electronic oil level control on every compressor.
  • Quiet enough for retailFrom 55 dB(A) at 10 m, with a low-noise enclosure available where neighbours or licensing demand it.
  • Two temperatures, one rackOrder MT-only for chilled duty, or an MT/LT booster to run the freezer room from the same machine.
  • Serviced locallySupplied, commissioned and maintained in Malaysia by RNA, with CO₂ training through the Beijer Ref Academy.

Where it is used

Segment Typical application
Retail Convenience stores, express supermarkets, mini-markets
Food service Restaurants, central kitchens, catering facilities
Fuel retail Petrol station shops and forecourt convenience formats
Small commercial Butcheries, bakeries, pharmacies, small cold rooms
Food storage Chiller and freezer rooms for food storage

Reading a model number

Every Smart Booster model code describes its own build. Once you can read it, you can identify any unit at a glance.

MWS 2x096 MTDX + UMCE 010 HBT

MWS
Smart Booster range
2x096
Two medium-temperature compressors, frame size 096
MTDX
Medium temperature, direct expansion
UMCE 010 HBT
One low-temperature compressor, size 010

Shortcut: no UMCE in the code means it is an MT-only unit. If UMCE is there, it is a full MT/LT booster.

All 22 models

Medium-temperature capacity is rated at −8 °C evaporating, 50 Hz, with a gas cooler outlet of 35 °C. Low-temperature capacity is rated at −30 °C evaporating, 50 Hz.

Find your model

Enter the duty you need and we will highlight the models that meet it. Leave low temperature blank for a chilled-only site.

 

Table A — MT only

For chilled duty: display cases, chillers and cold rooms above zero.

SCM Smart Booster MWS, medium-temperature-only models
Model number MT capacity kW Gas cooler kW I max A Weight kg dB(A) @10 m
MWS 2x043 MTDX 16.60 27 21.6 535 55
MWS 065+043 MTDX 21.80 34 26.8 540 56
MWS 2x065 MTDX 27.00 42 32.0 545 56
MWS 096+065 MTDX 33.40 52 38.4 550 57
MWS 2x096 MTDX 39.80 62 44.8 555 57
MWS 096+2x065 MTDX 46.50 73 54.4 690 58
MWS 2x096+065 MTDX 53.10 83 60.8 700 58
MWS 3x096 MTDX 59.50 93 67.2 710 59

Table B — MT/LT booster

For sites that need chilled and frozen duty from a single rack.

SCM Smart Booster MWS, medium and low temperature booster models
Model number MT capacity kW LT capacity kW Gas cooler kW I max A Weight kg dB(A) @10 m
MWS 2x043 MTDX + UMCE 007 HBT 12.21 3.30 27 24.5 650 55
MWS 065+043 MTDX + UMCE 007 HBT 17.40 3.30 34 29.7 655 56
MWS 2x065 MTDX + UMCE 007 HBT 22.60 3.30 42 34.9 660 56
MWS 2x065 MTDX + UMCE 010 HBT 20.35 5.20 42 35.7 662 56
MWS 096+065 MTDX + UMCE 010 HBT 26.72 5.20 52 42.1 667 57
MWS 2x096 MTDX + UMCE 010 HBT 33.15 5.20 62 48.5 670 57
MWS 2x096 MTDX + UMCE 020 HBT 32.00 6.61 62 50.1 675 57
MWS 2x096+065 MTDX + UMCE 020 HBT 44.60 6.61 83 66.1 845 59
MWS 3x096 MTDX + UMCE 020 HBT 50.90 6.61 93 72.5 850 59
MWS 2x096+065 MTDX + UMCE 030 HBT 42.50 8.53 83 67.0 853 59
MWS 3x096 MTDX + UMCE 030 HBT 48.85 8.53 93 73.4 857 59
MWS 096+065 MTDX + UMCE 2x007 HBT 25.10 6.57 52 44.2 805 57
MWS 2x096 MTDX + UMCE 2x007 HBT 31.50 6.57 62 50.6 810 57
Capacities are preliminary selection data. Final selection is confirmed against your site ambient, evaporating temperatures and load schedule.

Technical reference

Compressors fitted

The number in each model code identifies the compressor frame. Useful when ordering spares or planning service.

Code Duty BITZER model
MT CP 043 Medium temperature 4PTE-6K
MT CP 065 Medium temperature 4MTE-7K
MT CP 096 Medium temperature 4KTE-10K
LT CP 007 Low temperature 2MME-07K
LT CP 010 Low temperature 2KME-1K
LT CP 020 Low temperature 2JME-2K
LT CP 030 Low temperature 2HME-3K

Common data across the range

Parameter Specification
Refrigerant CO₂ / R744, GWP 1
Length, with front electrical board 1600 mm
Width 750 mm
Height 1990 mm
Liquid receiver volume 70 litres
MT capacity modulation, Varistep / CRII 10–100%
Electrical supply 400 V / 3+N / 50 Hz
Design pressure, high side 120 bar
Design pressure, receiver 80 bar
Design pressure, MT suction 60 bar, 80 bar optional
Design pressure, LT suction 60 bar, 80 bar optional
Maximum transcritical compressors 2–3
Maximum subcritical compressors 1–2

Standard equipment and options

Feature Standard Option
Electronic oil level regulator on each compressor Yes
Maintenance-free oil separator with oil reservoir Yes
Replaceable oil filter dryer Yes
Electronic minimum liquid level switch Yes
Liquid-flash internal heat exchanger Yes
Discharge manifold connected to safety valves Yes
Full factory testing and parameter setting Yes
CAREL controller with HP/MP valves Yes
Digital capacity modulation, CRII Yes
MT and LT suction filters Yes
Liquid filter dryer Yes
Frequency inverter on LT, 30–70 Hz Yes
Heat recovery with 3-way valve, tap water Yes
Low-noise enclosure, approx. 2564 × 1350 × 2240 mm Yes
Outdoor enclosure, boxed unit Yes
Electrical panel on short side Yes
Energy meter Yes
WURM controller in place of CAREL Yes
Mechanical subcooler Supplied spare
124 litre receiver, with ejector Yes

If the Smart Booster is too small

The same platform scales up through the SCM Frigo booster family. As a rule of thumb, a store with fewer than about 30 display cases and one freezer room starts with the Smart Booster.

Range Code Best for MT capacity LT capacity
Smart Booster MWS Convenience stores, small shops, restaurants 16.6–59.5 kW 3.3–8.5 kW
Lean Booster MWL Convenience stores, small supermarkets 15–100 kW 3–20 kW
Booster SMKT MWT Supermarkets, hypermarkets 75–350 kW 15–75 kW
Booster Industrial MWT-I Food processing, logistics centres 200–750 kW

Common questions

What is a CO₂ transcritical booster rack?

It is a refrigeration system that uses carbon dioxide, R744, as the refrigerant and serves both medium-temperature chilled loads and low-temperature frozen loads from one machine. Transcritical refers to the cycle CO₂ runs in warm ambient conditions, where heat is rejected through a gas cooler rather than a conventional condenser.

Is CO₂ refrigeration suitable for Malaysia's climate?

Yes, and it is already installed here. Transcritical systems are engineered for high-ambient operation, with parallel compression, ejectors and adiabatic gas coolers used specifically to hold efficiency in warm climates. Ambient temperature affects a CO₂ system more strongly than an HFC system, so every selection should be checked against your actual design conditions rather than catalogue figures alone. That check is part of how we quote.

Why move from R404A or R134a to CO₂?

CO₂ has a global warming potential of 1, against roughly 3,900 for R404A. It sits outside every phase-down schedule, costs little, and is available everywhere. Choosing it removes the risk of your refrigerant becoming restricted or expensive part-way through the equipment's working life.

How much space does a Smart Booster need?

The unit itself is 1600 mm long, 750 mm wide and 1990 mm high. Allow additional clearance for service access, plus space for the gas cooler and interconnecting pipework.

Can one rack run a freezer room and a chiller together?

Yes. Choose any MT/LT booster model, identified by UMCE in the model code, and the single rack handles both duties.

Do you install and service these in Malaysia?

Yes. RNA Engineering & Trading supplies, commissions and services SCM Frigo equipment throughout Malaysia, backed by the Beijer Ref group's CO₂ expertise and Beijer Ref Academy training.

What is the lead time?

The Smart Booster is a standardised range, which shortens manufacturing lead time compared with a bespoke rack. Contact us for current availability against your project programme.

Send us your load schedule

Give us your cabinet list, room volumes, evaporating temperatures and design ambient. We will come back with a model recommendation, a capacity check against your site conditions, and a budget price.