Muller BRGC CO2 Gas Cooler (R744)



 
 
 

R744 / CO2 central plant

BRGC CO2 Gas Coolers
& Remote Condensers

Eight models rejecting 69 kW to 345 kW at 36 °C ambient, built for transcritical CO2 supermarket and cold storage plant in Malaysia’s climate. Supplied and supported nationwide by RNA Engineering & Trading, a Beijer Ref company.

  • 130 bar design pressure
  • 910 mm EC axial fans
  • Horizontal or vertical discharge
  • Al/Mg fin as standard
BRGC three-fan CO2 remote gas cooler with 910 mm EC axial fans and painted steel casing
 

Built to reject CO2 heat in a tropical climate

The BRGC range is a remote gas cooler and condenser for R744 commercial central plant — supermarkets, cold rooms, distribution centres and air conditioning installations where low noise and low running cost matter.

In transcritical operation the CO2 leaves the compressor above its critical point and rejects heat without condensing, so the coil works as a gas cooler. When ambient falls and the plant drops below the critical point, the same unit works as a condenser. Both duties are published below so you can check the machine across the year rather than at one design point.

The coil surface to fan ratio is optimised so air distributes evenly at a reduced pressure drop across a wide fan speed range. That keeps electricity consumption down at part load, which is where a gas cooler spends most of its operating hours.

Features

  • 130 bar design pressure for transcritical CO2 duty
  • Copper connections and headers in CuFe2P
  • Fan motors factory pre-wired back to a junction box, so site wiring is one termination
  • Floating coil technology to absorb thermal movement
  • Aluminium/magnesium fin as standard; heavy duty coil coating available
  • Painted steel casing and end plates for a longer service life outdoors
  • Vertical or horizontal air discharge on every model

Options

  • Heavy duty electrocoat coil protection
  • Nano coated fin, rated 10,000 hours
  • Adiabatic sprays (parts only)
  • Overspray shield for adiabatic spray applications

BRGC model range

All eight models share the same 1382 mm deep casing and 910 mm EC fan platform. Length grows with fan count; capacity grows with coil rows.

Filters every table on this page at once.

Range at a glance — all BRGC models
Model number Fans Rows Capacity @ 36 °C, 980 rpm (kW) Length (mm) Weight, unpacked (kg) Connections (in)
BRGC113CREC 1 3 69.13 2200 373 1-1/8
BRGC115CREC 1 5 88.52 2200 400 1-1/8
BRGC123CREC 2 3 134.58 3950 590 1-1/8
BRGC125CREC 2 5 173.09 3950 715 1-1/8
BRGC133CREC 3 3 200.05 5700 820 1-3/8
BRGC135CREC 3 5 259.55 5700 1005 1-3/8
BRGC143CREC 4 3 263.43 7450 1085 1-3/8
BRGC145CREC 4 5 344.67 7450 1335 1-3/8

Capacity shown at transcritical condition, 36 °C ambient, maximum fan speed.

How to read the model number

BRGC133CREC
BRGC nomenclature
Position Example Meaning
BRGC BRGC Manufacturer — Beijer Ref Wuxi
Digit 1 1 Number of coils
Digit 2 3 Number of fans (1 to 4)
Digit 3 3 Number of rows (3 or 5)
Letter C Coil block variant / module, size C = 1750 mm
Letter R Fin type: R = Al/Mg raw, N = Al/Mg nano coated (10,000 hrs)
Suffix EC Electronically commutated fans

Airflow configuration is confirmed at time of order. Units ship as horizontal airflow unless vertical is specified.

Heat rejection capacity

Capacities are published at three fan speeds. Running a larger model at 850 or 680 rpm is often the cheaper long-term choice: fan power and sound both fall sharply while capacity holds up.

Transcritical — 36 °C ambient (tropical selection)

R744 · 36 °C ambient · 38 °C gas outlet · 92 bar · 115 °C discharge gas · 910 mm Axiblade

Total heat rejection, transcritical condition (36 °C)
Model number 980 rpm (max) 850 rpm 680 rpm
kW PD kPa kW PD kPa kW PD kPa
BRGC113CREC 69.13 71 62.08 48 53 44
BRGC115CREC 88.52 59 78.81 65 67 36
BRGC123CREC 134.58 65 121.01 54 103 41
BRGC125CREC 173.09 54 154.21 44 131 33
BRGC133CREC 200.05 62 179.81 52 154 39
BRGC135CREC 259.55 83 231.26 68 196 51
BRGC143CREC 263.43 43 236.86 35 203 27
BRGC145CREC 344.67 84 307.14 69 260 51

Subcritical — 20.5 °C ambient

R744 · 20.5 °C ambient · 28 °C SCT · 2K subcooling · 80 °C discharge gas

Total heat rejection, subcritical condition (20.5 °C)
Model number 980 rpm (max) 850 rpm 680 rpm
kW PD kPa kW PD kPa kW PD kPa
BRGC113CREC 56.13 132 50.24 113 42.79 87
BRGC115CREC 73.16 104 63.88 84 52.23 62
BRGC123CREC 110.15 124 98.55 106 82.41 81
BRGC125CREC 142.15 97 125.38 78 102.55 58
BRGC133CREC 161.46 121 146.76 103 123.76 79
BRGC135CREC 209.04 144 186.27 122 153.83 90
BRGC143CREC 217.82 90 192.88 75 164.85 57
BRGC145CREC 281.51 143 250.76 120 205.11 89

Transcritical — 30 °C ambient (European rating)

R744 · 30 °C ambient · 35 °C gas outlet · 90 bar · 110 °C discharge gas

Total heat rejection, transcritical condition (30 °C)
Model number 980 rpm (max) 850 rpm 680 rpm
kW PD kPa kW PD kPa kW PD kPa
BRGC113CREC 109.03 152 97.94 126 83.70 96
BRGC115CREC 143.02 134 127.44 109 107.90 82
BRGC123CREC 212.20 140 190.80 116 163.25 88
BRGC125CREC 279.58 124 249.36 101 211.37 76
BRGC133CREC 315.26 134 283.52 111 242.69 84
BRGC135CREC 418.74 189 373.50 155 316.61 116
BRGC143CREC 415.61 92 373.90 76 320.21 58
BRGC145CREC 556.05 190 496.05 156 420.59 117

Subcritical — 5 °C ambient (European rating)

R744 · 5 °C ambient · 15 °C SCT · 2K subcooling · 60 °C discharge gas

Total heat rejection, subcritical condition (5 °C)
Model number 980 rpm (max) 850 rpm 680 rpm
kW PD kPa kW PD kPa kW PD kPa
BRGC113CREC 90.26 322 81.26 267 68.94 199
BRGC115CREC 118.99 145 105.30 111 87.20 75
BRGC123CREC 178.22 306 158.58 253 134.16 188
BRGC125CREC 234.08 134 207.25 103 167.02 65
BRGC133CREC 263.74 300 236.66 248 199.99 184
BRGC135CREC 349.25 174 313.39 165 257.57 112
BRGC143CREC 350.90 236 312.11 192 263.32 139
BRGC145CREC 464.25 207 407.82 163 331.29 99

PD = refrigerant side pressure drop. Capacities are published manufacturer data at the stated conditions; final selection should be confirmed with a project-specific software selection.

Technical data

Motor, weight, coil and shipping data — 415 V / 3 ph EC, 910 mm standard fan
Model number Fan qty Max amps/ph Max input W Weight unpacked (kg) Weight packed (kg) Coil volume (dm³) Gas conn. ODS (mm) Liquid conn. ODS (mm) Shipping vol. (m³)
BRGC113CREC 1 3.9 2550 373 491 11.93 28.6 28.6 5.4
BRGC115CREC 1 3.9 2550 400 518 19.88 28.6 28.6 5.4
BRGC123CREC 2 7.8 5100 590 880 23.86 28.6 28.6 10.2
BRGC125CREC 2 7.8 5100 715 925 39.77 28.6 28.6 10.2
BRGC133CREC 3 11.7 7650 820 1250 35.79 34.9 34.9 14.6
BRGC135CREC 3 11.7 7650 1005 1330 59.66 34.9 34.9 14.6
BRGC143CREC 4 15.6 10200 1085 1560 47.73 34.9 34.9 19.1
BRGC145CREC 4 15.6 10200 1335 1810 79.52 34.9 34.9 19.1
Airflow and estimated input power
Model number Airflow (m³/h) Estimated input power (W)
980 rpm 850 rpm 680 rpm 980 rpm 850 rpm 680 rpm
BRGC113CREC 29,620 25,400 20,358 2025 1355 720
BRGC115CREC 27,450 23,520 18,879 2200 1470 780
BRGC123CREC 59,240 50,800 40,715 4050 2710 1440
BRGC125CREC 54,900 47,040 37,757 4400 2940 1560
BRGC133CREC 88,860 76,200 61,073 6075 4065 2160
BRGC135CREC 82,350 70,560 56,636 6600 4410 2340
BRGC143CREC 118,480 101,600 81,430 8100 5420 2880
BRGC145CREC 109,800 94,080 75,514 8800 5880 3120

Airflow and estimated input power from test results and fan manufacturer data.

Sound data — single coil models
Model number 980 rpm 850 rpm 680 rpm
LwA dB(A) LpA(3) dB(A) LwA dB(A) LpA(3) dB(A) LwA dB(A) LpA(3) dB(A)
BRGC113CREC 85.1 65.1 82.1 62.1 76.5 56.5
BRGC115CREC 86.6 66.6 83.7 63.7 77.7 57.7
BRGC123CREC 88.1 68.1 85.1 65.1 79.5 59.5
BRGC125CREC 89.6 69.6 86.7 66.7 80.7 60.7
BRGC133CREC 89.9 69.9 86.9 66.9 81.3 61.3
BRGC135CREC 91.4 71.4 88.5 68.5 82.5 62.5
BRGC143CREC 91.1 71.1 88.1 68.1 82.5 62.5
BRGC145CREC 92.6 72.6 89.7 69.7 83.7 63.7

LwA is sound power; LpA(3) is sound pressure at the published rating location. Dropping from 980 rpm to 680 rpm removes roughly 9 dB(A) — a useful lever for sites with a night-time noise limit. Full octave band spectra from 100 Hz to 8 kHz are available on request.

Dimensions and installation

Every model is available in horizontal or vertical air discharge. Casing depth and height change with the configuration; length and connection sizes do not.

Horizontal air discharge
Model number Fans Rows Liquid conn. (in) Suction conn. (in) W (mm) H (mm) L (mm)
BRGC113CREC 1 3 1-1/8 1-1/8 1382 1690 2200
BRGC115CREC 1 5 1-1/8 1-1/8 1382 1690 2200
BRGC123CREC 2 3 1-1/8 1-1/8 1382 1690 3950
BRGC125CREC 2 5 1-1/8 1-1/8 1382 1690 3950
BRGC133CREC 3 3 1-3/8 1-3/8 1382 1690 5700
BRGC135CREC 3 5 1-3/8 1-3/8 1382 1690 5700
BRGC143CREC 4 3 1-3/8 1-3/8 1382 1690 7450
BRGC145CREC 4 5 1-3/8 1-3/8 1382 1690 7450
Vertical air discharge
Model number Fans Rows Liquid conn. (in) Suction conn. (in) W (mm) H (mm) L (mm)
BRGC113CREC 1 3 1-1/8 1-1/8 1690 1905 / 1535 2200
BRGC115CREC 1 5 1-1/8 1-1/8 1690 1905 / 1535 2200
BRGC123CREC 2 3 1-1/8 1-1/8 1690 1905 / 1535 3950
BRGC125CREC 2 5 1-1/8 1-1/8 1690 1905 / 1535 3950
BRGC133CREC 3 3 1-3/8 1-3/8 1690 1905 / 1535 5700
BRGC135CREC 3 5 1-3/8 1-3/8 1690 1905 / 1535 5700
BRGC143CREC 4 3 1-3/8 1-3/8 1690 1905 / 1535 7450
BRGC145CREC 4 5 1-3/8 1-3/8 1690 1905 / 1535 7450

H (max) applies where a skirt is fitted. Mounting holes are Ø20 typical. Electrical box is mounted at the header end.

Where the BRGC is used

  • Supermarket and hypermarket CO2 booster racks
  • Cold storage and distribution centres
  • Food processing plant with central CO2 refrigeration
  • Convenience retail and quick-service restaurant chains standardising on R744
  • Commercial air conditioning central plant requiring low noise operation

Malaysia’s HFC phase-down under the Kigali Amendment is pushing new central plant towards natural refrigerants. CO2 has a GWP of 1, is not subject to quota, and keeps a site clear of future refrigerant supply risk. The gas cooler is the part of that system most exposed to local ambient, which is why the 36 °C selection data matters more here than the European rating.

Frequently asked questions

What is the difference between a CO2 gas cooler and a condenser?

In transcritical operation the CO2 is above its critical point when it leaves the compressor, so it cools without changing phase — that heat exchanger is a gas cooler. Below the critical point the CO2 condenses normally and the same coil acts as a condenser. The BRGC is rated for both duties, which is why two sets of capacity tables are published.

Which BRGC model should I select for a Malaysian site?

Start from the 36 °C transcritical table, since it sits close to local design ambient. Match your rack heat rejection to a model at the fan speed you plan to run. If the site has a noise limit or you want to cut fan energy, step up one model and run it at 850 or 680 rpm rather than running a smaller unit flat out.

What is the design pressure?

130 bar, with copper connections and headers in CuFe2P, suited to transcritical CO2 central plant.

Can it be supplied for vertical air discharge?

Yes, on all eight models. Airflow configuration is confirmed at time of order; units ship as horizontal airflow unless vertical is specified.

Is a corrosion protected coil available?

Aluminium/magnesium fin is standard. Nano coated fin rated to 10,000 hours and heavy duty electrocoat are available for coastal and chemically aggressive sites. Adiabatic spray parts and an overspray shield can also be supplied.

How is the unit wired on site?

All fan motors are factory pre-wired back to a junction box, so the site electrical contractor terminates once at the unit rather than wiring each fan individually.

Request a BRGC selection

RNA Engineering & Trading Sdn. Bhd. supplies, selects and supports the BRGC range across Malaysia, with technical backing from the wider Beijer Ref group.



 Inquiry - Muller BRGC CO2 Gas Cooler (R744)