Elitech MS-4000 4-Way Digital Manifold Set
Professional 4-way digital manifold for refrigeration and air-conditioning servicing, combining pressure, temperature, vacuum and refrigerant system analysis in one instrument.
MS-4000 4-Way Manifold Pressure + Temperature Superheat / Subcoolingโ๏ธ Elitech MS-4000 Digital Manifold Set
The Elitech MS-4000 4-Way Digital Manifold Set is a professional HVAC/R service instrument designed for refrigeration technicians who require more information than a conventional analogue manifold gauge can provide.
It combines high-side and low-side pressure measurement, dual temperature measurement, refrigerant pressure-temperature data, superheat/subcooling calculation and vacuum measurement into a single digital service platform.
Its 4-way manifold configuration provides additional flexibility when connecting refrigeration service equipment, making the MS-4000 suitable for installation, commissioning, charging, evacuation and system diagnosis.
๐ต๐กโซ๐ด Why Choose a 4-Way Digital Manifold?
The four-way manifold arrangement gives technicians more connection flexibility than a basic two-valve manifold, especially during charging, evacuation and other professional refrigeration service procedures.
A 4-way manifold configuration can simplify service setup by allowing multiple pieces of HVAC/R service equipment to remain connected during different stages of the job, depending on the technician's servicing procedure.
โญ Key Features
๐ Digital Pressure Measurement
Provides clear numerical high-side and low-side pressure readings for refrigeration and air-conditioning diagnosis.๐ก๏ธ Dual Temperature Measurement
Temperature probes allow technicians to monitor refrigeration line temperatures while checking system operating conditions.๐ฅ Superheat Calculation
Built-in calculation helps technicians evaluate superheat during refrigeration system commissioning and troubleshooting.โ๏ธ Subcooling Calculation
Calculate subcooling directly from measured system pressure and temperature information.๐ Vacuum Measurement
Supports vacuum monitoring as part of refrigeration system evacuation and commissioning.โ๏ธ Refrigerant Database
Built-in refrigerant pressure-temperature information supports multiple refrigerants used across HVAC/R systems.๐ง 4-Way Valve Design
Four-way manifold construction provides greater flexibility for charging, evacuation and service connections.๐บ Digital Display
Clearly displays important system information without requiring technicians to interpret mechanical dial scales.๐ One Instrument for Multiple HVAC/R Measurements
๐ต Low-Side Pressure
Monitor suction-side pressure during refrigeration system operation and servicing.๐ด High-Side Pressure
Monitor high-side pressure for refrigeration system analysis.๐ก๏ธ Pipe Temperature
Use compatible temperature probes to measure refrigerant line temperatures.๐ฅ Superheat
Calculate superheat from measured suction pressure and corresponding line temperature.โ๏ธ Subcooling
Calculate subcooling from high-side pressure and liquid-line temperature measurements.๐ Vacuum
Monitor vacuum conditions during system evacuation procedures.โ๏ธ Elitech MS-4000 Product Overview
| Specification / Function | MS-4000 |
|---|---|
| Brand | Elitech |
| Model | MS-4000 |
| Product Type | Digital Manifold Set |
| Manifold Configuration | 4-Way / 4-Valve |
| High-Side Pressure Measurement | Yes |
| Low-Side Pressure Measurement | Yes |
| Temperature Measurement | Yes |
| Dual Temperature Measurement | Yes |
| Superheat Calculation | Yes |
| Subcooling Calculation | Yes |
| Refrigerant PT Reference | Built-In Refrigerant Database |
| Vacuum Measurement | Yes |
| Temperature Units | °C / °F |
| Main Applications | Refrigerant Charging, Evacuation, Pressure Testing, System Commissioning & HVAC/R Diagnosis |
The advantage of the MS-4000 is that technicians can view pressure, temperature and calculated refrigeration parameters from the same service instrument, reducing the amount of manual PT-chart interpretation and calculation required during field servicing.
๐ก๏ธ Built-In Superheat & Subcooling Calculation
Superheat and subcooling are important refrigeration system parameters used by technicians when evaluating operating conditions and refrigerant charge.
๐ฅ Superheat
The manifold uses measured suction-side pressure and temperature information to help determine superheat.โ๏ธ Subcooling
High-side pressure and liquid-line temperature information can be used to calculate system subcooling.๐ Refrigerant PT Data
Built-in refrigerant pressure-temperature information helps eliminate repeated manual PT-chart lookup.โ๏ธ Suitable Applications
๐ง Cold Room Refrigeration
Suitable for cold room installation, commissioning, maintenance and refrigeration system diagnosis.๐ช Commercial Refrigeration
Useful for condensing units, display cases, freezers and other commercial refrigeration equipment.๐ฌ๏ธ Air Conditioning
Measure system pressure and temperature during air-conditioning installation and maintenance.๐จ Refrigerant Charging
Monitor refrigeration system conditions while carrying out appropriate refrigerant charging procedures.๐ System Evacuation
The four-way configuration provides additional connection flexibility during evacuation procedures.๐งฐ HVAC/R Troubleshooting
Pressure, temperature, superheat and subcooling information helps technicians evaluate refrigeration system operation.โ Why Choose Elitech MS-4000?
4-Way Professional Design
Provides additional connection flexibility compared with a basic two-valve manifold.Multiple Measurements
Combines pressure and temperature measurement with important refrigeration calculations.Digital Refrigerant Data
Built-in refrigerant PT information simplifies day-to-day HVAC/R service work.SH / SC Calculation
Built-in superheat and subcooling calculation reduces the need for manual calculations.Clear Digital Reading
Easy-to-read numerical information provides a modern alternative to conventional mechanical dial gauges.Professional HVAC/R Tool
Suitable for refrigeration contractors, technicians, installation teams and maintenance departments.โ ๏ธ Important Usage Information
• Select the correct refrigerant before using refrigerant PT calculations.
• Confirm that system pressure is within the instrument's specified operating range.
• Connect high-side and low-side hoses to the appropriate service ports.
• Use suitable hoses, fittings and service equipment for the refrigerant being handled.
• Superheat and subcooling values should be interpreted according to the refrigeration system design and manufacturer's specifications.
• Use an appropriate dedicated micron gauge when the job requires precise deep-vacuum verification.
• Follow applicable refrigerant handling and HVAC/R safety procedures.
Elitech MS-4000 4-Way Digital Manifold Supplier Malaysia
RNA Engineering & Trading Sdn Bhd supplies the Elitech MS-4000 4-Way Digital Manifold Set for air conditioning, cold room, commercial refrigeration and professional HVAC/R servicing applications.
Contact our sales team for product availability, technical enquiries and refrigeration service equipment.