Elitech Smart Vacuum Pump
Professional 2-stage smart vacuum pump for faster and more intelligent evacuation of air conditioning, cold room and refrigeration systems.
V700 • V900 • V1200 7–12 CFM 15 Micron Ultimate Vacuum Bluetooth + Smart App🚀 Elitech Smart Vacuum Pump for HVAC/R
The Elitech Smart Vacuum Pump is a professional 2-stage refrigeration vacuum pump designed to make HVAC/R evacuation more intelligent, visible and manageable than conventional vacuum pumping.
Available in V700, V900 and V1200, the range provides pumping capacities from 7 CFM to 12 CFM, allowing technicians to select a pump according to refrigeration system size and evacuation requirements.
Unlike a conventional vacuum pump that simply runs until it is manually switched off, Elitech integrates a full-color touchscreen, vacuum monitoring, Bluetooth/App connectivity, evacuation data recording and intelligent monitoring functions into the pump.
🔍 Choose Your Elitech Smart Vacuum Pump
V700
7 CFM / 3 L/sMotor: 3/4 HP / 550 W
Ultimate Vacuum: 15 Microns
Stage: 2-Stage
Weight: Approx. 14.8 kg
Ideal when a more compact pumping capacity is suitable for the refrigeration service application.
V900
9 CFM / 4 L/sMotor: 1 HP / 750 W
Ultimate Vacuum: 15 Microns
Stage: 2-Stage
Weight: Approx. 15.3 kg
A balanced mid-range choice for professional refrigeration and air-conditioning evacuation work.
V1200
12 CFM / 5 L/sMotor: 1 HP / 750 W
Ultimate Vacuum: 15 Microns
Stage: 2-Stage
Weight: Approx. 16 kg
Highest pumping capacity in this range for applications requiring faster evacuation of larger system volumes.
🧠 More Than a Conventional Vacuum Pump
📉 Real-Time Vacuum Monitoring
Monitor the refrigeration system vacuum level directly during the evacuation process.📈 Vacuum Trend Graph
View vacuum changes graphically to better understand the progress of system evacuation.📱 Bluetooth + Smart App
Monitor evacuation information remotely through Elitech's compatible Smart HVAC App.🖥️ Full-Color Touchscreen
Large 800 × 480 full-color touchscreen provides clear operating and vacuum information.💾 Offline Data Storage
Stores up to 60,000 data points for evacuation records and later analysis.📤 Data Recording & Export
Record and export evacuation data for service documentation and system analysis.🔄 OTA Firmware Update
Supports App-based OTA functionality for compatible firmware updates.🌡️ Smart Monitoring
Monitors operating conditions including pump oil and motor temperature during evacuation.⚙️ V700 vs V900 vs V1200 Specifications
| Specification | V700 | V900 | V1200 |
|---|---|---|---|
| Stage | 2-Stage | 2-Stage | 2-Stage |
| Pumping Rate | 7 CFM / 3 L/s | 9 CFM / 4 L/s | 12 CFM / 5 L/s |
| Ultimate Vacuum | 15 Microns | 15 Microns | 15 Microns |
| Motor | AC Induction Motor | AC Induction Motor | AC Induction Motor |
| Motor Power | 3/4 HP / 550 W | 1 HP / 750 W | 1 HP / 750 W |
| Speed Regulation | Fixed Speed | Fixed Speed | Fixed Speed |
| Power Supply | 110V / 60Hz or 220V / 50–60Hz* | ||
| Operating Temperature | 5°C to 40°C / 41°F to 104°F | ||
| Display | 800 × 480 Full-Color Touchscreen | ||
| Bluetooth / App | ✓ | ✓ | ✓ |
| OTA Firmware Update | ✓ | ✓ | ✓ |
| Data Recording / Export | ✓ | ✓ | ✓ |
| Offline Data Storage | Up to 60,000 Data Points | ||
| Wireless Distance | Approx. 10 m / 30 ft | ||
| Air Inlet | 1/4″ SAE + 3/8″ SAE | ||
| Oil Capacity | 650 ml / 22 oz | 650 ml / 22 oz | 750 ml / 25.3 oz |
| Dimensions | Approx. 470 × 267 × 380 mm | ||
| Weight | 14.8 kg | 15.3 kg | 16 kg |
The main difference is pumping capacity: V700 provides 7 CFM, V900 provides 9 CFM and V1200 provides 12 CFM. A higher CFM rating provides greater pumping capacity, which can be advantageous when evacuating larger-volume systems.
📊 See the Evacuation Process – Not Just the Pump
One of the key advantages of the Elitech Smart Vacuum Pump is the ability to provide technicians with information about what is happening during evacuation.
📉 Vacuum Level
Monitor the measured vacuum level while evacuation is taking place.📈 Vacuum Curve
Observe vacuum changes graphically rather than relying only on pump running time.⏱️ Process Monitoring
Follow evacuation progress and operating information from the touchscreen or compatible App.📝 Service Records
Record evacuation information to support better service documentation and job records.🧰 Typical Refrigeration Evacuation Process
Complete the appropriate refrigeration system pressure test and leak inspection before beginning evacuation.
Connect suitable vacuum-rated hoses and service equipment to the refrigeration system.
Run the Elitech Smart Vacuum Pump and monitor the vacuum level and evacuation trend.
Continue evacuation until the required system vacuum specified by the equipment manufacturer or commissioning procedure has been achieved.
Isolate the system and observe vacuum behaviour to help evaluate whether the system is ready for the next commissioning stage.
❄️ Suitable Applications
🧊 Cold Room Systems
Ideal for evacuation during new cold room refrigeration installation and commissioning.🏪 Commercial Refrigeration
Suitable for condensing units, freezers, display cases and commercial refrigeration systems.🌬️ Air Conditioning
Professional evacuation equipment for compatible air-conditioning installation and service work.🏭 Larger Refrigeration Systems
V900 and V1200 provide higher pumping capacities for applications involving larger system volumes.🔧 HVAC/R Maintenance
Useful for refrigeration repair, compressor replacement and system maintenance requiring evacuation.⚙️ System Commissioning
Vacuum monitoring and recording help support professional refrigeration commissioning procedures.✅ Why Choose Elitech Smart Vacuum Pump?
2-Stage Pump
Professional two-stage design engineered for deep HVAC/R system evacuation.15-Micron Ultimate Vacuum
Specified ultimate vacuum down to 15 microns.7–12 CFM Range
Three pumping capacities allow selection according to different HVAC/R servicing requirements.Smart Touchscreen
View important operating and evacuation information directly from the pump.Bluetooth Monitoring
Compatible App connectivity allows technicians to monitor evacuation information wirelessly.Data Recording
Store, record and export evacuation data for professional service documentation.⚠️ Important Usage Information
• Select the appropriate pump capacity for the refrigeration system.
• Check vacuum pump oil condition and level before operation.
• Use suitable vacuum-rated hoses and fittings to reduce evacuation restriction.
• Confirm the electrical supply matches the vacuum pump version supplied.
• Do not judge system evacuation only by running time; follow the equipment manufacturer's required vacuum and commissioning procedure.
• A vacuum rise after isolation can have several causes, including moisture, leakage or trapped refrigerant; diagnose according to proper HVAC/R procedures.
• Follow applicable refrigeration and electrical safety procedures.
Elitech Smart Vacuum Pump Supplier Malaysia
RNA Engineering & Trading Sdn Bhd supplies Elitech Smart Vacuum Pumps for air conditioning, cold room, commercial refrigeration and professional HVAC/R installation and servicing applications.
Contact our sales team for model selection, product availability, technical enquiries and refrigeration service equipment.
Inquiry - Elitech Smart Vacuum Pump