2

Share:


Danfoss Gas Detector



DANFOSS REFRIGERANT GAS DETECTION

Danfoss Leak Detector – DGS Refrigerant Gas Detection Series

The Danfoss DGS Leak Detector is designed for continuous, real-time monitoring of refrigerant gases in commercial and industrial refrigeration applications.

Different DGS sensor configurations are available for HFC/HFO refrigerants and CO₂ (R744), allowing the correct sensing technology and enclosure to be selected according to the refrigeration system and installation environment.

DGS Series Refrigerant Leak Detection HFC / HFO CO₂ / R744 IP41 / IP66 Modbus

🛡️ Refrigerant Leak Detection for Multiple Refrigerants

The Danfoss DGS range is not limited to CO₂. It provides gas detection solutions for a wide selection of refrigerants used throughout commercial and industrial refrigeration systems.

DGS sensors continuously monitor refrigerant concentration in the surrounding environment and can provide alarm and control signals when the detected concentration reaches the configured threshold.

One DGS Family – Different Refrigerant Applications

The correct DGS detector should be selected according to the refrigerant, sensor technology, environmental conditions and installation requirements.

🔍 DGS Sensor Technologies

DGS-SC

Semiconductor Sensor

Designed for detection of various fluorinated refrigerants. Different code numbers are calibrated for different refrigerants or refrigerant groups.

Examples:
R404A • R507 • R134a • R407A • R407F • R410A • R448A • R449A • R1234ze • R422D

DGS-IR CO₂

Infrared Sensor

Designed specifically for detection of carbon dioxide / R744 used as a natural refrigerant.

Refrigerant:
CO₂ / R744

📋 DGS IP41 Enclosure Models

IP41 versions from this DGS generation are intended for installation environments within the applicable temperature and enclosure requirements.

Refrigerant DGS Type Code No. Enclosure Temperature
R404A / R507 DGS-SC 080Z2998 IP41 −20°C to +50°C
R134a DGS-SC 080Z2942 IP41 −20°C to +50°C
R407A DGS-SC 080Z2943 IP41 −20°C to +50°C
R407F DGS-SC 080Z2956 IP41 −20°C to +50°C
R410A DGS-SC 080Z2988 IP41 −20°C to +50°C
R448A DGS-SC 080Z2945 IP41 −20°C to +50°C
R449A DGS-SC 080Z2947 IP41 −20°C to +50°C
R1234ze DGS-SC 080Z2985 IP41 −20°C to +50°C
CO₂ / R744 DGS-IR CO₂ 080Z2995 IP41 −20°C to +50°C
CO₂ / R744 DGS-IR CO₂ Failsafe 080Z2994 IP41 −20°C to +50°C

💧 DGS IP66 Enclosure Models

IP66 versions provide a higher enclosure protection level and the catalogue specifies operation down to −40°C for this generation.

Refrigerant DGS Type Code No. Enclosure Temperature
R404A / R507 DGS-SC 080Z2999 IP66 −40°C to +50°C
R134a DGS-SC 080Z2989 IP66 −40°C to +50°C
R407A DGS-SC 080Z2944 IP66 −40°C to +50°C
R407F DGS-SC 080Z2957 IP66 −40°C to +50°C
R410A DGS-SC 080Z2987 IP66 −40°C to +50°C
R422D DGS-SC 080Z2949 IP66 −40°C to +50°C
R448A DGS-SC 080Z2946 IP66 −40°C to +50°C
R449A DGS-SC 080Z2948 IP66 −40°C to +50°C
R1234ze DGS-SC 080Z2986 IP66 −40°C to +50°C
CO₂ / R744 DGS-IR CO₂ 080Z2996 IP66 −40°C to +50°C
CO₂ / R744 DGS-IR CO₂ Failsafe 080Z2993 IP66 −40°C to +50°C
CO₂ / R744 DGS-IR CO₂ Remote Sensor 080Z2997 IP66 −40°C to +50°C
CO₂ / R744 DGS-IR CO₂ Remote Sensor / Failsafe 080Z2992 IP66 −40°C to +50°C
CO₂ / R744 DGS-IR CO₂ Duct Mounted Sensor 080Z2958 IP66 −40°C to +50°C

⚖️ IP41 vs IP66 – What's the Difference?

IP41 Version

Typical catalogue temperature: −20°C to +50°C

Suitable where the installation environment does not require the higher ingress protection of the IP66 enclosure.

IP66 Version

Typical catalogue temperature: −40°C to +50°C

Higher enclosure protection makes this version suitable for more demanding refrigeration environments, subject to the installation requirements.

⭐ Key Features & Benefits

🔄 Continuous Monitoring

Automatic real-time refrigerant gas monitoring for refrigeration applications.

❄️ Multiple Refrigerants

DGS configurations are available for numerous HFC/HFO refrigerants as well as CO₂ / R744.

📡 Modbus Communication

Can communicate with compatible refrigeration control and monitoring systems using Modbus.

📊 Analogue Output

Provides analogue output capability for integration with compatible control systems.

🚨 Alarm Function

Designed to provide alarm indication when detected gas concentration reaches the configured limit.

🏢 Flexible Integration

Suitable for stand-alone operation or integration with refrigeration monitoring and Building Management Systems.

🏭 Typical Applications

🛒 Supermarkets

Refrigerant leak monitoring for supermarket refrigeration systems and machinery areas.

❄️ Cold Rooms

Gas monitoring for commercial and industrial cold-storage applications.

📦 Refrigerated Warehouses

Continuous refrigerant monitoring for refrigerated storage facilities.

🏭 Process Refrigeration

Suitable for compatible process and industrial refrigeration installations.

⚙️ Equipment Areas

Point detection can be positioned near equipment where a refrigerant leak is considered more likely.

🏢 Commercial Refrigeration

Suitable for various commercial refrigeration applications using compatible refrigerants.

🎯 How to Select the Correct DGS Leak Detector

1️⃣ Identify Refrigerant

First determine the refrigerant used by the refrigeration system.

2️⃣ Select Sensor Type

Choose the appropriate DGS sensor technology for the target refrigerant.

3️⃣ Choose IP Rating

Select IP41 or IP66 according to the environmental and installation requirements.

4️⃣ Check Temperature

Verify that the detector's operating-temperature range is suitable for the installation area.

5️⃣ Installation Type

For applicable CO₂ systems, standard, remote-sensor and duct-mounted configurations are available.

6️⃣ Confirm Code Number

For replacements, provide the complete existing Danfoss code number before ordering.
⚠️ Important:

Gas-detector selection and positioning depend on refrigerant type, refrigerant density, room layout, ventilation and applicable safety requirements. Always follow the latest Danfoss installation instructions and applicable local regulations.

Danfoss Leak Detector Supplier Malaysia

RNA Engineering & Trading Sdn Bhd supplies Danfoss DGS refrigerant leak detectors, refrigeration controls, sensors and HVACR spare parts for commercial refrigeration, cold rooms and industrial refrigeration systems.

Contact us for pricing, availability and technical enquiries.



 Inquiry - Danfoss Gas Detector