Share:


Totaline Low Pressure Switch



TOTALINE LOW PRESSURE CONTROL

Totaline PA37 & PS021-0004L Low Pressure Switch

Compact fixed-setting low pressure switches for air-conditioning and refrigeration systems, designed to monitor suction-side pressure and provide reliable pressure-responsive switching for compatible HVACR equipment.

PA37 PS021-0004L Low Pressure Fixed Setting R22 R410A

❄️ Totaline Low Pressure Switch

The Totaline PA37 and PS021-0004L Low Pressure Switches are compact pressure controls for compatible air-conditioning and refrigeration applications.

A low pressure switch is normally connected to the low-pressure / suction side of a refrigeration circuit. It monitors suction pressure and changes its electrical contact state when pressure falls to its predetermined OFF pressure.

When system pressure rises again to the specified ON pressure, the switch returns to its corresponding operating state, allowing it to form part of a properly designed compressor or equipment control circuit.

Simple, Practical & Value-Focused Pressure Control

The Totaline design combines a compact pressure switch, factory-set switching points and pre-wired cable in a straightforward replacement component for compatible HVACR equipment.

📋 Available Models

Totaline PA37

ON 60 PSI / OFF 30 PSI Low Pressure R22 Fixed Setting

Fixed-setting low pressure switch for compatible R22 air-conditioning and refrigeration systems.

ON: 60 PSI ≈ 4.14 bar
OFF: 30 PSI ≈ 2.07 bar
Cable Length: 1500 mm

Totaline PS021-0004L

ON 115 PSI / OFF 65 PSI Low Pressure R410A Fixed Setting

Fixed-setting low pressure switch designed for compatible R410A air-conditioning and refrigeration systems.

ON: 115 PSI ≈ 7.93 bar
OFF: 65 PSI ≈ 4.48 bar
Cable Length: 1000 mm

🔄 How a Low Pressure Switch Works

1 ❄️ Normal Operation
The switch monitors pressure on the low-pressure side of the refrigeration circuit.
2 📉 Pressure Falls
Suction pressure decreases according to the system operating condition.
3 🔴 OFF Point
When pressure reaches the fixed OFF value, the electrical contact changes state.
4 🛡️ Control Responds
The equipment control circuit responds to the low-pressure switch signal.
5 📈 Pressure Recovers
Low-side pressure rises again when system conditions recover.
6 🟢 ON Point
At the specified ON pressure, the switch returns to its corresponding operating state.

🛡️ Why Low Pressure Control Is Important

Low suction pressure can occur for several reasons in an air-conditioning or refrigeration system. A low-pressure switch provides a pressure-responsive electrical signal that can be incorporated into the equipment's control and protection strategy.

❄️ Low Suction Pressure Monitors pressure on the low side of compatible refrigeration and air-conditioning systems.
💨 Refrigerant Flow Conditions Changes in refrigerant flow or system load can affect suction pressure.
🧊 Evaporator Conditions Abnormal evaporator operating conditions may result in lower-than-intended suction pressure.
⚙️ Compressor Control Can form part of a properly designed compressor control circuit.
🔄 Pressure-Based Switching Provides repeatable switching at predetermined pressure points without field adjustment.
🔧 Replacement Application Useful for service replacement when model, pressure settings and equipment specifications match.

💰 Why Choose Totaline Low Pressure Switch?

🎯 Factory-Set Pressure Points Fixed ON and OFF settings simplify selection and remove the need for field pressure adjustment.
📦 Compact Construction Small switch body is convenient for installation inside compatible air-conditioning and refrigeration equipment.
🔌 Pre-Wired Cable Supplied with cable for straightforward integration into compatible equipment wiring.
❄️ Application-Specific Options PA37 provides an R22 option while PS021-0004L provides an R410A pressure configuration.
🔧 Service-Friendly Replacement Clear model and switching-pressure identification helps technicians match the correct replacement.
💰 Strong Value A straightforward fixed-setting design provides the required pressure-switching function without the complexity of an adjustable electronic controller.
Quality + Practicality + Value
For equipment requiring these specific fixed pressure settings, Totaline PA37 and PS021-0004L provide a practical HVACR replacement solution backed by the Totaline parts brand.

🏭 Typical Applications

🌬️ Air Conditioning Low-pressure monitoring in compatible air-conditioning and cooling equipment.
❄️ Commercial Refrigeration Pressure switching for compatible refrigeration systems and equipment.
⚙️ Condensing Units Low-side pressure control for compatible refrigeration condensing units.
🧊 Refrigeration Systems Pressure-responsive control for compatible evaporator and compressor circuits.
🔧 HVACR Maintenance Replacement component for service and repair when specifications match the original switch.
🏢 Commercial Cooling Equipment Suitable for compatible commercial HVACR equipment requiring fixed low-pressure switching.

🔧 How to Select the Correct Model

Selection Point PA37 PS021-0004L
Pressure Function Low Pressure Low Pressure
ON Pressure 60 PSI 115 PSI
OFF Pressure 30 PSI 65 PSI
Listed Refrigerant R22 R410A
Cable Length 1500 mm 1000 mm
Selection Always match the original equipment pressure setting, refrigerant, pressure connection and electrical requirements.
⚠️ Important: Do not select a low-pressure switch only because the product looks physically similar. Verify the complete model, ON pressure, OFF pressure, refrigerant application, pressure connection and electrical requirements against the original equipment before replacement.

📌 Understanding ON & OFF Pressure

🔴 OFF Pressure When low-side pressure falls to this predetermined value, the switch changes electrical state.
🟢 ON Pressure When pressure rises again to this value, the switch returns to its corresponding operating state.
PA37: 60 PSI ON ← Pressure Recovers   |   Pressure Falls → 30 PSI OFF

PS021-0004L: 115 PSI ON ← Pressure Recovers   |   Pressure Falls → 65 PSI OFF

Totaline Low Pressure Switch Supplier Malaysia

RNA Engineering & Trading Sdn Bhd supplies Totaline pressure switches and HVACR spare parts for air-conditioning, commercial refrigeration and cooling-system applications.

Contact our team for pricing, availability, replacement matching and product selection.



 Inquiry - Totaline Low Pressure Switch