MULLER INDUSTRIAL REFRIGERATION

Muller GTA Series Industrial Dual Blow Unit Cooler

High-Capacity Dual Throw Evaporator for Commercial & Industrial Refrigeration

The Muller GTA Series is an industrial dual blow / dual throw unit cooler designed for large temperature-controlled spaces, processing areas and commercial refrigeration applications. The range combines large Ø630 mm fans, 4.23 mm fin spacing and multiple 4-, 6- and 8-row coil configurations, with published SC2 performance data for R404A and R22.

↔️ Dual Blow Design 💨 Ø630 mm Fans ⚙️ 2–4 Fans 🧊 4.23 mm Fin Spacing 📋 9 Models ♻️ R404A / R22

Designed as a large industrial dual-discharge unit cooler, the GTA Series uses a white pre-painted galvanized-steel casing and is available in nine model configurations. The published range covers two, three and four Ø630 mm fan arrangements together with 4-, 6- and 8-row coils. The coil configurations are optimized for direct-expansion applications, while glycol-water application is identified as an available option.

📌 GTA Series at a Glance

📋
9 Models BGTA24R6 through BGTA48R6
💨
2–4 Fans Ø630 mm industrial fans
❄️
22.5–70.2 kW Published SC2 capacity range across listed data
🧊
4.23 mm Standard fin spacing / 6 FPI

✨ GTA Series Design Features

↔️

Dual Blow Air Distribution

Industrial dual-discharge construction distributes conditioned air in two directions across the refrigerated area.

💨

Ø630 mm Fans

The published GTA range uses Ø630 mm, 380V / 3PH / 50Hz fans in two-, three- and four-fan configurations.

🛡️

Galvanized-Steel Casing

Standard construction uses a white pre-painted galvanized-steel casing.

💧

Hinged Drain Pans

Removable drain pans are fixed by hinges, with condensate evacuated through two large drain pipes.

🔧

Easy Service Access

Removable end covers provide convenient access for installation and maintenance.

🌀

Serviceable Fan Panels

Fan units are mounted on articulated panels to simplify maintenance work.

🔎 GTA Model Range

The published GTA range combines 2-, 3- and 4-fan configurations with 4-, 6- and 8-row coil arrangements.

BGTA24R6 2 Fans • 4 Rows
BGTA26R6 2 Fans • 6 Rows
BGTA28R6 2 Fans • 8 Rows
BGTA34R6 3 Fans • 4 Rows
BGTA36R6 3 Fans • 6 Rows
BGTA38R6 3 Fans • 8 Rows
BGTA44R6 4 Fans • 4 Rows
BGTA46R6 4 Fans • 6 Rows
BGTA48R6 4 Fans • 8 Rows

⚡ Delta & Star Fan Operation

D — DELTA

890 r/min

The catalogue provides a Delta operating point at 890 r/min, with corresponding airflow, air throw, power, current and SC2 cooling capacity.

Y — STAR

690 r/min

The Star operating point is published at 690 r/min, providing a separate lower-speed performance point for each GTA model.

🌡️ SC2 Standard Rating Condition

0°C Air Inlet Temperature
-8°C Evaporating Temperature
8K Standard Temperature Difference
4.23 mm Fin Spacing

📊 GTA Series Technical Performance

Published performance at SC2. D = Delta connection at 890 r/min; Y = Star connection at 690 r/min.

Model Surface
m²
Internal
Volume dm³
No. of
Rows
Fan Dia.
mm
No. of
Fans
Motor
Connection
Total Power
W
Total Current
A
Air Throw
m
Air Flow
m³/h
R404A
kW @ SC2
R22
kW @ SC2
Optional Heater
W
BGTA24R6 130 25.2 4 630 2 D 1,200 2.40 2×12 17,770 27.1 26.1 13,500
Y 800 1.36 2×10 13,770 23.5 22.5
BGTA26R6 195 37.8 6 630 2 D 1,200 2.40 2×11 16,780 30.9 29.6 13,500
Y 800 1.36 2×9 12,750 26.2 25.1
BGTA28R6 260 50.4 8 630 2 D 1,200 2.40 2×10 15,920 34.7 33.3 13,500
Y 800 1.36 2×8 11,930 28.8 27.6
BGTA34R6 195 37.8 4 630 3 D 1,800 3.60 2×12 26,650 40.1 38.5 20,700
Y 1,200 2.04 2×10 20,540 34.8 33.4
BGTA36R6 292 56.7 6 630 3 D 1,800 3.60 2×11 25,180 49.7 47.7 20,700
Y 1,200 2.04 2×9 19,130 41.5 39.9
BGTA38R6 390 75.7 8 630 3 D 1,800 3.60 2×10 23,880 52.3 50.2 20,700
Y 1,200 2.04 2×8 17,900 43.1 41.4
BGTA44R6 260 50.4 4 630 4 D 2,400 4.80 2×12 35,540 54.7 52.5 27,000
Y 1,600 2.72 2×10 27,390 47.1 45.2
BGTA46R6 390 75.7 6 630 4 D 2,400 4.80 2×11 33,570 62.1 59.6 27,000
Y 1,600 2.72 2×9 25,510 52.8 50.7
BGTA48R6 520 100.9 8 630 4 D 2,400 4.80 2×10 31,840 70.2 67.3 27,000
Y 1,600 2.72 2×8 23,860 57.8 55.5

🧮 Room Temperature Correction Factors

Published GTA Series room-temperature correction factors.

0°C Room Temperature Factor 1.00
2°C Room Temperature Factor 1.07
4°C Room Temperature Factor 1.14
6°C Room Temperature Factor 1.20
15°C Room Temperature Factor 1.20

⚙️ Standard Construction & Available Options

STANDARD

EBM AC Motor

EBM AC motor is identified as the standard motor configuration.

STANDARD

Galvanized-Steel Casing

White pre-painted galvanized-steel casing.

STANDARD

4.23 mm Fin Spacing

6 FPI / 4.23 mm fin spacing is standard.

OPTIONAL

Blue Fin Coating

Blue-fin coating is listed as an optional fin treatment.

OPTIONAL

Black Electrophoresis Coating

Black electrophoresis fin coating is available as an option.

OPTIONAL

Stainless-Steel Casing

Stainless-steel casing is listed as an alternative option.

OPTIONAL

Insulated Double Drain Pan

Insulated double drain-pan construction is available.

OPTIONAL

Electrical Defrost

Electrical defrost for coil and drain pan is available.

OPTIONAL

Hot Gas Defrost

Hot-gas coil defrost with electrical drain-pan defrost is listed as an option.

OPTIONAL

Fan Wiring

Fan wiring is listed as an optional configuration.

N/A

Water Defrost

Water defrost is marked as unavailable in the reference catalogue.

N/A

Other Listed Motors

Interlink and Ziehl-Abegg motors are marked N/A for this GTA configuration.

Configuration Note: The catalogue states that coil electrical heating and black electrophoresis fin coating cannot be used together.

📐 Dimensions, Connections & Net Weight

Published connection sizes are product inlet/outlet dimensions. Actual refrigerant connecting-line dimensions should be calculated according to the application.

2554 mm Overall length – 2-fan GTA configuration
3604 mm Overall length – 3-fan GTA configuration
4658 mm Overall length – 4-fan GTA configuration
View Model Connections & Net Weight
Model Liquid Inlet
OD, inch
Suction Outlet
OD, inch
Net Weight
kg
BGTA24R6 1 1/8" 1 3/8" 260
BGTA26R6 1 1/8" 1 5/8" 292
BGTA28R6 1 3/8" 1 5/8" 316
BGTA34R6 1 3/8" 2 1/8" 349
BGTA36R6 1 5/8" 2 1/8" 395
BGTA38R6 1 5/8" 2 1/8" 433
BGTA44R6 1 5/8" 2 1/8" 457
BGTA46R6 1 5/8" 2 1/8" 506
BGTA48R6 1 5/8" 2 5/8" 549
General dimensional reference: The published drawing shows an overall unit width of approximately 1500 mm, an overall height of 663 mm, and Ø32 mm drain connections. Refer to the dimensional drawing when planning installation clearance.

🏭 Typical GTA Series Applications

🥩
Food Processing Areas
👷
Refrigerated Workrooms
🛒
Supermarket Refrigeration
❄️
Cold Rooms
📦
Cold Storage Areas
🏭
Industrial Refrigeration
🌡️
Temperature-Controlled Areas
⚙️
Process Cooling Applications

🎯 Information Required for GTA Model Selection

For accurate selection, compare the actual refrigeration-system conditions with the published SC2 performance.

Required Capacity Cooling load required in kW
Refrigerant Confirm system refrigerant
Room Temperature Required refrigerated-space temperature
Evaporating Temperature Required system evaporating condition
Fan Operation Delta or Star operating requirement
Airflow Requirement Compare with published m³/h performance
Coil Configuration 4-, 6- or 8-row model
Defrost Requirement Confirm whether defrost option is required
Installation Space Confirm unit size and service clearance
⚠️ Important Selection Note: The capacities shown on this page are based on the published SC2 condition of 0°C air inlet temperature, -8°C evaporating temperature and 8K temperature difference. Actual refrigeration capacity varies with operating conditions, refrigerant, room temperature, airflow, fan operating mode and system design. Final model and refrigerant-line selection should therefore be checked against the actual project conditions.

Need Help Selecting a Muller GTA Series Unit Cooler?

Send us your required cooling capacity, room temperature, evaporating temperature, refrigerant, room dimensions and application. We can assist in comparing the GTA Series 2-, 3- and 4-fan configurations and the published SC2 performance for your refrigeration project.