Copeland Moisture Indicator / Sight Glass (Emerson Alco)
Brand: Copeland
Copeland Emerson ALCO Sight Glass / Moisture Indicator
Professional refrigeration liquid-line sight glasses and moisture indicators designed for visual monitoring of refrigerant condition and moisture level inside commercial refrigeration and HVAC systems.
HMI-S Series AMI-1 TT Series AMI-1 SS Series AMI-2 Series Liquid Line Monitoring Moisture IndicationCopeland Sight Glass / Moisture Indicator
The Copeland Emerson ALCO Sight Glass / Moisture Indicator provides refrigeration technicians with a convenient inspection point in the liquid refrigerant line.
The viewing window helps technicians observe liquid refrigerant condition, while the moisture-sensitive indicator helps identify excessive moisture inside the refrigeration system.

HMI-S vs AMI Series
The HMI-S Series uses a compact hermetic construction designed for reliable liquid-line monitoring with minimal service requirements.
✓ Hermetic sealed construction
✓ Liquid refrigerant viewing window
✓ Moisture-sensitive indicator
✓ Compact installation design
✓ Extended ODF solder connection models
✓ Suitable for commercial refrigeration systems
The AMI Series provides a serviceable moisture indicator design with multiple connection configurations and larger connection-size options.
✓ Serviceable construction
✓ Replaceable indicator / lens assembly
✓ Moisture-sensitive indication
✓ Wide viewing area
✓ Multiple ODF connection configurations
✓ Available for larger refrigeration liquid lines
HMI-S → Hermetic / sealed design
AMI-1 TT → Serviceable, extended ODF connection
AMI-1 SS → Serviceable, standard ODF connection
AMI-2 → Serviceable design for larger line sizes
Available Copeland Sight Glass Models
Click any series below to expand the complete model, PCN and connection-size information.
HMI-S Series – Hermetic Moisture Indicator
| Model | PCN | Connection Size | Connection Type |
|---|---|---|---|
| HMI-S TT 2 | 067116 | 1/4" | Extended ODF Solder |
| HMI-S TT 3 | 067115 | 3/8" | Extended ODF Solder |
| HMI-S TT 4 | 067107 | 1/2" | Extended ODF Solder |
| HMI-S TT 5 | 067108 | 5/8" | Extended ODF Solder |
| HMI-S TT 6 | 067118 | 3/4" | Extended ODF Solder |
| HMI-S TT 7 | 067117 | 7/8" | Extended ODF Solder |
| HMI-S TT 9 | 067114 | 1-1/8" | Extended ODF Solder |
AMI-1 TT Series – Extended ODF Solder
| Model | PCN | Connection Size | Connection Type |
|---|---|---|---|
| AMI-1 TT 2 | 047298 | 1/4" | Extended ODF Solder |
| AMI-1 TT 3 | 042771 | 3/8" | Extended ODF Solder |
| AMI-1 TT 4 | 022302 | 1/2" | Extended ODF Solder |
| AMI-1 TT 5 | 031136 | 5/8" | Extended ODF Solder |
| AMI-1 TT 7 | 031357 | 7/8" | Extended ODF Solder |
| AMI-1 TT 9 | 031578 | 1-1/8" | Extended ODF Solder |
| AMI-1 TT 11 | 060255 | 1-3/8" | Extended ODF Solder |
AMI-1 SS Series – Standard ODF Solder
| Model | PCN | Connection Size | Connection Type |
|---|---|---|---|
| AMI-1 SS 2 | 048811 | 1/4" | ODF Solder |
| AMI-1 SS 3 | 048812 | 3/8" | ODF Solder |
| AMI-1 SS 4 | 048813 | 1/2" | ODF Solder |
| AMI-1 SS 5 | 048814 | 5/8" | ODF Solder |
| AMI-1 SS 7 | 048815 | 7/8" | ODF Solder |
| AMI-1 SS 9 | 048816 | 1-1/8" | ODF Solder |
AMI-2 Series – Large Line Size
| Model | PCN | Connection Size | Connection Style |
|---|---|---|---|
| AMI-2 S 11 | 022303 | 1-3/8" | Bushing Style |
| AMI-2 S 13 | 028388 | 1-5/8" | Bushing Style |
| AMI-2 S 17 | 031219 | 2-1/8" | Bushing Style |
How a Refrigeration Sight Glass Works
Why Moisture Control Is Important
Moisture inside a refrigeration system can contribute to several operating problems, including ice formation at expansion devices, corrosion, lubricant deterioration and the formation of harmful acids.
A moisture indicator provides technicians with a quick visual reference so that abnormal system moisture conditions can be identified during routine servicing and troubleshooting.
Important Sight Glass Troubleshooting Note
Bubbles inside a liquid-line sight glass may indicate insufficient liquid refrigerant at the sight glass, but they do not automatically mean the refrigeration system is undercharged. Possible causes can include:
✓ Low refrigerant charge
✓ Excessive liquid-line pressure drop
✓ Restricted filter drier
✓ Flash gas
✓ Insufficient subcooling
✓ Abnormal operating conditions
For accurate diagnosis, always check system pressures, temperatures, superheat and subcooling together with the sight-glass condition.
Quick Selection Guide
Typical Applications
Why Choose Copeland / Emerson ALCO?
✓ Established refrigeration control product range
✓ Reliable liquid-line visual monitoring
✓ Moisture-sensitive indicator technology
✓ Hermetic and serviceable product designs
✓ Multiple ODF connection sizes available
✓ Suitable for commercial refrigeration applications
✓ Useful for installation, servicing and system troubleshooting
Copeland Sight Glass Supplier in Malaysia
Looking for a suitable Copeland Emerson ALCO Sight Glass or Moisture Indicator for your refrigeration system?
Available families include HMI-S, AMI-1 TT, AMI-1 SS and AMI-2 with multiple connection sizes for commercial refrigeration, cold-room and freezer applications.
Provide your existing model, PCN, refrigerant and connection size for suitable product matching.
Inquiry - Copeland Moisture Indicator / Sight Glass (Emerson Alco)