Share:


Teidar Suction Accumulator



Teidar TDQ Suction Accumulator

Refrigeration suction line accumulator designed to help protect the compressor against liquid refrigerant floodback while supporting reliable oil return in refrigeration and air-conditioning systems.

TDQ Series 1/2″ – 3-1/8″ Compressor Protection Commercial Refrigeration

Teidar Refrigeration Suction Accumulator

The Teidar TDQ Suction Accumulator is installed in the suction line before the compressor to help prevent excessive liquid refrigerant from entering the compressor.

During conditions where liquid refrigerant returns from the evaporator, the accumulator temporarily retains the liquid and allows refrigerant to return toward the compressor in a more controlled manner. This helps reduce the risk associated with liquid refrigerant floodback.

Product Highlights

Compressor Protection Helps prevent excessive liquid refrigerant from returning directly to the compressor.
Controlled Refrigerant Return Internal construction helps manage accumulated refrigerant before it returns toward the compressor.
Oil Return Support Designed to support proper return of refrigeration oil together with refrigerant during system operation.
Wide Model Range Available in different body capacities and connection sizes for small to large commercial refrigeration systems.

Popular Teidar TDQ Models We Supply

Model Connection Size Product
TDQ-204 1/2″ AVAILABLE MODEL
TDQ-595 5/8″ AVAILABLE MODEL
TDQ-596 3/4″ AVAILABLE MODEL
TDQ-5127 7/8″ AVAILABLE MODEL
TDQ-5139 1-1/8″ AVAILABLE MODEL
TDQ-51711 1-3/8″ AVAILABLE MODEL
TDQ-62013 1-5/8″ AVAILABLE MODEL
TDQ-221 2-1/8″ AVAILABLE MODEL
TDQ-225 2-5/8″ AVAILABLE MODEL
TDQ-231 3-1/8″ AVAILABLE MODEL

Additional Teidar TDQ Technical Model Range

The following models are shown in the Teidar technical data. Dimensions d1 and d2 refer to the connection dimensions, while ØA × B represents the accumulator body dimensions.

Model d1 d2 L1 L2 L3 ØA × B Bolt Volume
TDQ-2055A1 16.2 16.2 35 35 65 114×200 A-1 2.0 L
TDQ-2055 16.2 16.2 35 35 65 114×200 M10×20 2.0 L
TDQ-2066A1 19.2 19.2 35 35 65 114×200 A-1 2.0 L
TDQ-2066 19.2 19.2 35 35 65 114×200 M10×20 2.0 L
TDQ-2266D2 19.2 19.2 35 35 65 127×200 D-2 2.2 L
TDQ-3066A1 19.2 19.2 35 35 70 127×300 A-1 3.0 L
TDQ-3066 19.2 19.2 35 35 70 127×300 M10×20 3.0 L
TDQ-3077A1 22.2 22.2 40 40 70 127×300 A-1 3.0 L
TDQ-3077 22.2 22.2 40 40 70 127×300 M10×20 3.0 L
TDQ-3266 19.2 19.2 35 35 70 127×280 M10×20 3.2 L
TDQ-3566A4 19.2 19.2 35 35 70 127×300 A-4 3.5 L
TDQ-3566 19.2 19.2 35 35 70 127×300 M10×20 3.5 L
TDQ-3577A4 22.2 22.2 40 40 70 127×300 A-4 3.5 L
TDQ-3577 22.2 22.2 40 40 70 127×300 M10×20 3.5 L
TDQ-4266 19.2 19.2 35 35 70 127×360 M10×20 4.2 L
TDQ-4666A4 19.2 19.2 35 35 85 159×280 A-4 4.6 L
TDQ-4666 19.2 19.2 35 35 85 159×280 M10×20 4.6 L
TDQ-4677A4 22.2 22.2 40 40 85 159×280 A-4 4.6 L
TDQ-4677 22.2 22.2 40 40 85 159×280 M10×20 4.6 L
TDQ-5299 28.6 28.6 45 45 85 159×320 M10×20 5.2 L
TDQ-6366A4 19.2 19.2 35 35 85 159×313 A-4 6.3 L
TDQ-6366 19.2 19.2 35 35 85 159×313 M10×20 6.3 L
TDQ-6377A4 22.2 22.2 40 40 85 159×313 A-4 6.3 L
TDQ-6377 22.2 22.2 40 40 85 159×313 M10×20 6.3 L
TDQ-6599 28.6 28.6 45 45 85 159×330 M10×20 6.5 L
TDQ-8099A5 28.6 28.6 45 45 85 159×407 A-5 8.0 L
TDQ-100116 35 35 45 45 85 159×595 M10×20 10 L
TDQ-100118 35 35 45 45 115 219×307 M10×20 10 L
TDQ-12099 28.6 28.6 45 45 85 219×362 M10×20 12 L
TDQ-23013 42 42 50 50 115 219×650 4×Φ6 23 L
Technical table: Dimensional values above are reproduced from the Teidar technical information supplied with this product. Dimensions are in millimetres unless otherwise indicated.

How a Suction Accumulator Protects the Compressor

Evaporator Refrigerant leaves the evaporator and travels through the suction line.
TDQ Suction Accumulator Excess liquid refrigerant is temporarily retained instead of flowing directly into the compressor.
Compressor Refrigerant and oil are returned toward the compressor in a more controlled manner.

Typical Applications

Teidar TDQ Suction Accumulators can be used in suitable cold rooms, freezers, low-temperature refrigeration, commercial refrigeration systems, condensing units, refrigeration racks, heat pumps and other HVAC/R systems where liquid refrigerant floodback is a concern.

How to Select a Suction Accumulator

The correct accumulator should be selected according to the refrigerant, system capacity, suction connection size, evaporating temperature, expected liquid holding requirement and compressor operating conditions.

Important: Do not select a suction accumulator based only on pipe connection size. Accumulator volume and actual refrigeration system operating conditions must also be considered.

Teidar Suction Accumulator Supplier in Malaysia

RNA Engineering & Trading Sdn Bhd supplies Teidar TDQ Suction Line Accumulators for commercial refrigeration, cold room and air-conditioning applications.

Provide your refrigerant, compressor model, system capacity and suction pipe size for suitable model selection.



 Inquiry - Teidar Suction Accumulator