2

Share:


Muller Cabinet Cooler BC BF Series



MULLER COMMERCIAL REFRIGERATION

Muller Cabinet Cooler BC & BF Series

Medium & Low Temperature Commercial Refrigeration Unit Coolers

The Muller Cabinet Cooler BC & BF Series provides compact forced-air evaporator solutions for commercial refrigeration applications. The range includes BC Series medium-temperature models and BF Series low-temperature models, with multiple cooling capacities, airflow configurations, fan sizes and refrigerant performance ratings available for system selection.

❄️ Medium Temperature 🧊 Low Temperature 💨 Forced Air Cooling 📋 16 Available Models ⚙️ Commercial Refrigeration

Designed for commercial refrigeration applications where compact installation and effective air circulation are important, the Muller Cabinet Cooler range offers different configurations for medium- and low-temperature duties. The supplied technical data covers cooling capacities at 6KTD, TX valve configuration, airflow, fan diameter, fan quantity, electrical current and drain-pan construction, with electric heater data additionally provided for the BF low-temperature range.

📌 Product Range at a Glance

📋
16 Models 10 BC models + 6 BF models
❄️
BC Series Medium-temperature cabinet coolers
🧊
BF Series Low-temperature cabinet coolers
💨
72 – 380 L/s Published airflow range across BC & BF models

🔍 Choose Your Muller Cabinet Cooler Series

The range is divided into two temperature application groups for easier product selection.

MEDIUM TEMPERATURE

❄️ Muller BC Series

The BC Series is the medium-temperature range with capacity data published for R404A, R134a and R22. Ten models are available from BC301 through BC2100.

10 Models R404A R134a R22 72–380 L/s
LOW TEMPERATURE

🧊 Muller BF Series

The BF Series is the low-temperature range with published capacity data for R404A and R22. Six models are available from BF450 through BF1650, with electric heater data included in the supplied technical specifications.

6 Models R404A R22 Electric Heater 120–380 L/s

✨ Product Features

📐

Compact Cabinet Design

Cabinet-style evaporator configuration for commercial refrigeration applications where installation space matters.

🌡️

Two Temperature Ranges

Separate BC medium-temperature and BF low-temperature model ranges simplify application selection.

💨

Forced-Air Cooling

Multiple fan configurations provide published airflow from 72 L/s up to 380 L/s depending on model.

⚙️

Multiple Model Sizes

Sixteen available BC and BF models provide a broad selection of cooling capacities and airflow configurations.

🔧

TX Valve Configurations

Manufacturer technical data identifies models with Int. or Ext. TX valve configurations according to model.

🔥

BF Electric Heater Data

BF low-temperature models include published 240V, 50/60Hz electric heater wattage and current data.

📊 Technical Data

Click each series below to view the complete model specifications.

❄️ BC Series — Medium Temperature Technical Data
Capacity rating: Published cooling capacities are shown in Watts @ 6KTD. BC Series data includes R404A, R134a and R22.
Model R404A
W @ 6KTD
R134a
W @ 6KTD
R22
W @ 6KTD
TX Valve Air Flow
L/s
Fan Dia.
mm
Fan
Qty
Total Amps
50Hz
Total Amps
60Hz
Drain Pan
BC301 360 320 310 Int. 72 178 1 0.26 0.26 White ABS Plastic
BC401 490 420 430 Int. 77 178 1 0.26 0.26 White ABS Plastic
BC550 630 520 570 Int. 110 178 2 0.43 0.43 White ABS Plastic
BC651 730 600 670 Int. 105 178 2 0.47 0.47 White ABS Plastic
BC750 850 700 770 Int. 120 178 2 0.43 0.43 White ABS Plastic
BC1001 1180 970 1060 Int. 165 178 3 0.72 0.72 White ABS Plastic
BC1201 1280 1140 1200 Int. 175 178 3 0.65 0.65 White ABS Plastic
BC1350 1580 1220 1420 Ext. 265 178 3 0.82 0.82 White ABS Plastic
BC1700 1880 1460 1700 Ext. 380 200 3 0.67 0.67 Stucco Aluminium
BC2100 2350 1810 2100 Ext. 350 200 3 0.67 0.67 Stucco Aluminium
🧊 BF Series — Low Temperature Technical Data
Capacity rating: Published cooling capacities are shown in Watts @ 6KTD. BF Series data includes R404A and R22 plus electric heater specifications at 240V, 50/60Hz.
Model R404A
W @ 6KTD
R22
W @ 6KTD
TX Valve Air Flow
L/s
Fan Dia.
mm
Fan
Qty
Total Amps
50Hz
Total Amps
60Hz
Heater
Watts
Heater
Total Amps
Drain Pan
BF450 470 440 Int. 120 178 2 0.43 0.43 460 1.9 White ABS Plastic
BF600 620 590 Int. 160 178 3 0.72 0.72 720 3.0 White ABS Plastic
BF750 790 710 Ext. 175 178 3 0.65 0.65 720 3.0 White ABS Plastic
BF1000 1170 1000 Ext. 270 178 3 0.82 0.82 1225 5.1 White ABS Plastic
BF1380 1470 1380 Ext. 380 200 3 0.67 0.67 1700 7.1 Stucco Aluminium
BF1650 1710 1650 Ext. 350 200 3 0.67 0.67 2200 9.2 Stucco Aluminium

🔩 Drain Pan Construction

White ABS Plastic

Specified in the supplied technical data for BC301 through BC1350 and BF450 through BF1000.

Stucco Aluminium

Specified for the larger BC1700, BC2100, BF1380 and BF1650 models.

🏪 Typical Applications

Muller BC & BF Cabinet Coolers are designed for compact commercial refrigeration applications requiring forced-air evaporator cooling.

🧊
Refrigerated Cabinets
🏪
Commercial Refrigeration
🥤
Chilled Display Equipment
❄️
Low Temperature Cabinets
🍽️
Food Service Refrigeration
🛒
Retail Refrigeration
📦
Chilled Storage Equipment
⚙️
OEM Refrigeration Equipment

🎯 Information Required for Model Selection

Do not select a cabinet cooler from the model number alone. Compare the actual refrigeration operating requirements with the published performance data.

1. Temperature Application Medium temperature or low temperature
2. Required Capacity Determine the actual refrigeration cooling load
3. Refrigerant Match the appropriate published refrigerant data
4. Temperature Difference Published table capacities are rated at 6KTD
5. Airflow Compare required air circulation with model airflow
6. Fan Configuration Check fan diameter, quantity and electrical current
7. TX Valve Confirm the required Int. / Ext. configuration
8. Defrost Requirement Review BF electric heater data for low-temperature duty
9. Installation Space Confirm physical installation requirements before ordering
⚠️ Important Selection Note: Cooling capacities shown in the tables are the published values at 6KTD from the supplied technical data. Actual system performance depends on the selected refrigerant, operating temperatures, temperature difference, system design and application conditions. Confirm the required duty and technical conditions before final model selection.

Looking for a Muller BC or BF Cabinet Cooler?

Contact us with your required cooling capacity, operating temperature, refrigerant, application and available installation space. Our team can assist with comparing the Muller BC medium-temperature and BF low-temperature cabinet cooler models for your commercial refrigeration application.



 Inquiry - Muller Cabinet Cooler BC BF Series