1

Share:


Muller Dual Blower TA Series



MULLER COMMERCIAL REFRIGERATION

Muller Dual Blower TA Series Unit Cooler

Commercial Dual Blow Unit Cooler for High & Medium Temperature Applications

The Muller TA Series Dual Blower Unit Cooler is a ceiling-mounted commercial evaporator designed for applications where quiet operation, compact installation and effective two-way air distribution are required. The range covers both high-temperature R Series and medium-temperature L Series configurations.

↔๏ธ Dual Blow Design ๐Ÿ”‡ Quiet Operation โ„๏ธ High & Medium Temp ๐Ÿ’จ 350 mm Fans ๐Ÿ“‹ 14 Model Configurations โ™ป๏ธ R404A / R22 Data

Designed for ceiling installation, the TA Series commercial dual blow unit cooler distributes air from both sides of the unit, making it suitable for temperature-controlled spaces where direct high-velocity air discharge over products or working areas may be undesirable. The range includes seven sizes in both high- and medium-temperature configurations, giving a total of 14 standard model configurations.

Product Range at a Glance

๐Ÿ“‹
14 Models 7 High Temp + 7 Medium Temp
๐Ÿ’จ
350 mm Fans Hermetic fan configuration
↔๏ธ
Dual Blow Two-way air distribution design
๐Ÿ”‡
29–35 dB(A) Published Lp4m sound pressure range

๐Ÿช Recommended Applications

The TA Series catalogue identifies the following commercial refrigeration market segments and applications.

๐Ÿ›’
Supermarkets
๐Ÿญ
Food Processing Rooms
๐Ÿ“ฆ
Packing Rooms
๐Ÿงช
Laboratories
โ„๏ธ
Cold Storage
๐Ÿฝ๏ธ
Food Preparation Areas
๐Ÿฅฉ
Temperature-Controlled Food Areas
โš™๏ธ
Commercial Refrigeration

โœจ Key Design Features

↔๏ธ

Dual Blow Airflow

Ceiling-mounted design distributes conditioned air from both sides of the unit cooler.

๐Ÿ”‡

Quiet Operation

Designed for applications where low operating noise is an important consideration.

๐Ÿ’จ

350 mm Fans

Standard fan data specifies 350 mm diameter, 1000 RPM, 220V / 1PH / 50Hz fans.

๐Ÿ›ก๏ธ

ABS Engineering Plastic

ABS casing with rounded corners, integral fan hood and anti-corrosion treatment.

๐Ÿ’ง

Intermediate Drain Pan

Intermediate drain-pan construction helps avoid condensation forming on the casing.

๐Ÿ”ฅ

Defrost Options

Electrical and hot-gas defrost configurations are identified in the catalogue options table.

๐ŸŒก๏ธ High Temperature vs Medium Temperature

R SERIES

TA...R6P — High Temperature

High-temperature configuration with standard 3.63 mm fin spacing. Published standard rating condition is 10°C air inlet temperature, 0°C evaporating temperature and 10K temperature difference.

3.63 mm Fin Spacing TD = 10K 7 Models R404A / R22
L SERIES

TA...L6P — Medium Temperature

Medium-temperature configuration with standard 6.35 mm fin spacing. Published standard rating condition is 0°C air inlet temperature, -8°C evaporating temperature and 8K temperature difference.

6.35 mm Fin Spacing TD = 8K 7 Models R404A / R22

๐Ÿ”Ž TA Series Nomenclature

Use the model code to identify the series number, temperature range, motor type, defrost configuration and order code.

TA 1 R 6P - H C
1 / 2 / 3 ... Series number / unit size
R High Temperature – 3.63 mm fin spacing
L Medium Temperature – 6.35 mm fin spacing
6P 6-pole motor
H Electrical defrost
Blank Without defrost
N InterLink
C Order code

๐Ÿ“Š TA Series Technical Data

Click each temperature range to view the complete performance data.

๐Ÿ”ฅ TA...R6P High Temperature — 3.63 mm Fin Spacing
Standard rating condition: Air inlet = 10°C • Evaporating temperature = 0°C • TD = 10K • Fan = 350 mm, 1000 RPM, 220V / 1PH / 50Hz
Model R22
Capacity kW
R404A
Capacity kW
Internal
Volume dm³
Surface
m²
Fans
Qty
Air Flow
m³/h
Air Throw
m
Fan Power
W
Fan Current
A max
Heater
W
Net Weight
kg
Sound Lp4m
dB(A)
TA1R6P 3.85 3.93 15.23 2.23 1 1310 7 1×68 1×0.30 800 22 29
TA2R6P 5.23 6.09 15.23 2.23 2 2910 7 2×68 2×0.30 800 28.3 32
TA3R6P 6.96 7.46 22.84 3.35 2 2750 7 2×68 2×0.30 1200 31 32
TA4R6P 7.83 8.06 30.45 4.46 2 2615 7 2×68 2×0.30 1600 33.6 32
TA5R6P 10.49 11.26 34.26 5.02 3 4125 7 3×68 3×0.30 1800 37.4 34
TA6R6P 12.90 13.21 57.10 8.36 3 3765 6 3×68 3×0.30 3000 45.7 34
TA7R6P 15.84 16.32 60.91 8.92 4 5230 7 4×68 4×0.30 3200 60.9 35
โ„๏ธ TA...L6P Medium Temperature — 6.35 mm Fin Spacing
Standard rating condition: Air inlet = 0°C • Evaporating temperature = -8°C • TD = 8K • Fan = 350 mm, 1000 RPM, 220V / 1PH / 50Hz
Model R22
Capacity kW
R404A
Capacity kW
Internal
Volume dm³
Surface
m²
Fans
Qty
Air Flow
m³/h
Air Throw
m
Fan Power
W
Fan Current
A max
Heater
W
Net Weight
kg
Sound Lp4m
dB(A)
TA1L6P 2.36 2.38 2.79 11.33 1 1330 7 1×68 1×0.30 800 23.3 29
TA2L6P 3.76 3.86 3.35 13.60 2 2875 7 2×68 2×0.30 800 25.9 32
TA3L6P 4.44 4.48 4.46 18.13 2 2760 7 2×68 2×0.30 1200 29 32
TA4L6P 4.82 4.89 5.58 22.66 2 2660 7 2×68 2×0.30 1600 34 32
TA5L6P 5.46 5.51 5.02 20.40 3 4315 7 3×68 3×0.30 1800 38.5 34
TA6L6P 7.60 7.70 8.36 33.99 3 3990 7 3×68 3×0.30 3000 47.4 34
TA7L6P 9.78 9.82 11.15 45.32 4 5315 7 4×68 4×0.30 3200 57.5 35

๐ŸŒก๏ธ Standard Rating Conditions

๐Ÿ”ฅ TA...R6P High Temperature

Air Inlet Temperature +10°C
Evaporating Temperature 0°C
Standard TD 10K
Standard Fin Spacing 3.63 mm

โ„๏ธ TA...L6P Medium Temperature

Air Inlet Temperature 0°C
Evaporating Temperature -8°C
Standard TD 8K
Standard Fin Spacing 6.35 mm

๐Ÿงฎ Fin Material Correction Factors

Aluminium Fin

Published correction factor

1.00

Coated Aluminium Fin

Published correction factor

0.97

๐Ÿ“ TA Series Dimensions

Dimensions below correspond to TA unit sizes 1 through 7.

TA Size A
mm
B
mm
C
mm
Liquid Inlet
mm
Vapor Outlet
mm
TA 1 886 17.5 560 15.88 15.88
TA 2 1366 17.5 1060 15.88 15.88
TA 3 1366 17.5 1060 15.88 22.22
TA 4 1366 17.5 1060 15.88 22.22
TA 5 1866 35 1560 15.88 22.22
TA 6 1866 35 1560 15.88 28.58
TA 7 2366 35 2060 15.88 28.58

โš™๏ธ Configuration & Options

Motor

InterLink motor is identified as the standard motor configuration.

Fin Coating

Blue-fin coated aluminium is listed as an optional configuration.

Casing

ABS engineering plastic casing is identified as standard.

Electrical Defrost

Electrical defrost is standard for the medium-temperature configuration and optional for the high-temperature range.

Hot Gas Defrost

Hot-gas defrost coil is listed as an available option.

Fin Spacing

Published options include 3.63 mm, 4.23 mm, 5.08 mm and 6.35 mm fin spacing depending on configuration.

โš ๏ธ Important Selection Note: The capacities shown above are based on the catalogue's published standard rating conditions. Actual cooling capacity varies with refrigerant, evaporating temperature, entering-air temperature, temperature difference, fin material and actual system conditions. The catalogue also states that the listed liquid/vapor connection dimensions are product outlet dimensions; the actual connecting-line size should be calculated according to the application.

Looking for a Muller TA Series Dual Blower Unit Cooler?

Contact us with your required cooling capacity, refrigerant, room temperature, evaporating temperature and application. We can assist in comparing the TA high-temperature and medium-temperature configurations for your commercial refrigeration project.



 Inquiry - Muller Dual Blower TA Series