Share:


Danfoss CI Contactor



DANFOSS ELECTRICAL MOTOR CONTROL

Danfoss CI Contactor

CI 5- Minicontactors • CI 6–50 • CI 61–98

A comprehensive contactor range for motor switching, refrigeration, air-conditioning, HVAC/R and industrial electrical-control applications, covering compact minicontactors through larger motor contactors.

⚡ Reliable Electrical Switching & Motor Control

Danfoss CI Contactors are designed for reliable switching of motors and other electrical equipment. The CI programme covers a wide range of current and motor-power requirements, from compact control applications to larger industrial motor loads.

Different models are available with various main-contact configurations, auxiliary-contact options and coil/control voltages, allowing the correct contactor to be selected according to the electrical system and motor load.

📊 Danfoss CI Contactor Range

COMPACT RANGE
CI 5-
CI5-5 • CI5-9 • CI5-12
Up to 5.5 kW
STANDARD RANGE
CI 6–30
CI6 • CI9 • CI12 • CI15 • CI16 • CI20 • CI25 • CI30
Up to 15 kW @ 380–690V
HIGHER CAPACITY
CI 32–50
CI32 • CI37 • CI45 • CI50
Up to 25 kW @ 380–690V
LARGE CONTACTORS
CI 61–98
CI61 • CI73 • CI86 • CI98
Up to 55 kW @ 380–690V

🔍 Complete Danfoss CI Model Selector

Click each range below to view model ratings and base ordering codes.

CI 5- Minicontactors — CI5-5 / CI5-9 / CI5-12

Compact Danfoss minicontactors designed for applications where installation space is limited.

Type AC-3 Current 230–240V 400–690V Main Contacts Built-in Aux. Base Code
CI 5-5 10 4.9 A 1.5 kW 2.2 kW 3 1 NO 037H3502
CI 5-5 01 4.9 A 1.5 kW 2.2 kW 3 1 NC 037H3503
CI 5-9 10 8.5 A 3.0 kW 4.0 kW 3 1 NO 037H3504
CI 5-9 01 8.5 A 3.0 kW 4.0 kW 3 1 NC 037H3505
CI 5-9 M40 8.5 A 3.0 kW 4.0 kW 4 — 037H3506
CI 5-12 10 11.5 A 3.0 kW 5.5 kW 3 1 NO 037H3507
CI 5-12 01 11.5 A 3.0 kW 5.5 kW 3 1 NC 037H3508
Related Control Relays: CI 5-2 40E (037H3500 – 4 NO) and CI 5-2 22Z (037H3501 – 2 NO + 2 NC).
CI 6–15 — Compact Contactors
Type AC-3 Current 220–240V 380–690V Contacts Base Code
CI 6 6 A 1.5 kW 2.2 kW 3 Main 037H0015
CI 6 6 A 1.5 kW 2.2 kW 4 Main 037H0018
CI 9 9 A 2.2 kW 4.0 kW 3 Main 037H0021
CI 9 ⭐ 9 A 2.2 kW 4.0 kW 4 Main 037H0022
CI 12 12 A 3.0 kW 5.5 kW 3 Main 037H0031
CI 12 ⭐ 12 A 3.0 kW 5.5 kW 4 Main 037H0032
CI 15 16 A 4.0 kW 7.5 kW 3 Main 037H0049
CI 15 16 A 4.0 kW 7.5 kW 4 Main 037H0050
CI 16–30 — Medium Capacity Contactors
Type AC-3 Current 220–240V 380–690V Base Code
CI 16 16 A 4.0 kW 7.5 kW 037H0041
CI 20 20 A 5.5 kW 10.0 kW 037H0045
CI 25 ⭐ 25 A 5.5 kW 11.0 kW 037H0051
CI 30 32 A 8.5 kW 15.0 kW 037H0055
CI 32–50 — Higher Capacity Contactors
Type AC-3 Current 220–240V 380–690V Base Code
CI 32 32 A 8.5 kW 15 kW 037H0061
CI 37 37 A 10 kW 18.5 kW 037H0056
CI 45 45 A 11 kW 22 kW 037H0071
CI 50 52 A 15 kW 25 kW 037H0080
CI 61–98 — Large Motor Contactors
Type AC-3 Current 220–240V 380–690V Base Code
CI 61 60 A 18.5 kW 30 kW 037H3061
CI 73 72 A 22 kW 37 kW 037H3062
CI 86 85 A 25 kW 45 kW 037H3063
CI 98 97 A 30 kW 55 kW 037H3040

⚡ Understanding Danfoss Contactor Coil Voltage

The complete Danfoss ordering code depends on the contactor base code and the required coil voltage/frequency. The last two digits of many CI contactor codes identify the coil-voltage version.

Example:
037H0032 + 37 = 037H003237
CI 12, 4 main contacts + 380–400V 50Hz / 440V 60Hz coil
CI 5- Coil Voltage Options
Coil Voltage Suffix
24V 50/60Hz 13
110V 50Hz / 120V 60Hz 23
230V 50/60Hz 32
240V 50/60Hz 33
400V 50/60Hz 37
24V DC 02
CI 6–30 AC Coil Voltage Options
Coil Voltage / Frequency Suffix
24V 50–60Hz 13
24V 50Hz / 29V 60Hz 16
42V 50Hz / 50V 60Hz 17
110V 50Hz / 110–120V 60Hz 23
208–230V 60Hz 28
220–240V 50Hz 31
220–230V 50Hz / 220V 60Hz 32
380–400V 50Hz / 440V 60Hz 37
415V 50Hz / 500V 60Hz 38
500V 50Hz / 600V 60Hz 94

✨ Key Features

⚡ Wide Power Range
Compact through larger contactor options for different motor and electrical loads.
🔌 Multiple Coil Voltages
Different control-voltage options are available according to contactor family and model.
🧩 Flexible Accessories
Selected ranges support auxiliary contacts, timers, mechanical interlocks and other accessories.
🛡️ Motor Control
Suitable for integration with appropriate motor-protection and control equipment.

🏭 Typical Applications

❄️ Refrigeration Systems
🧊 Cold Room Equipment
⚙️ Compressor Motor Control
💨 Condenser & Evaporator Fans
🏢 Air-Conditioning Systems
🏭 Industrial Motor Control
🔌 Electrical Control Panels
🔧 HVAC/R Service & Replacement

📋 How to Select the Correct Danfoss CI Contactor

For correct contactor selection, please confirm the following electrical and application information:

✓ Existing Contactor Model
✓ Danfoss Part Number
✓ Motor Power (kW / HP)
✓ Motor Full Load Current
✓ Main Supply Voltage
✓ Coil / Control Voltage
✓ Number of Main Contacts
✓ Auxiliary Contact Requirement
⚠️ Important Contactor Selection Note

Do not select a replacement contactor by CI model number alone. Contactors of the same CI size may have different coil voltages, main-contact configurations and control requirements.